28
9.
|
/
~
for the required value.
Heating curve
HC1
Slope
100°C
20
10
0
-10
-20
-30
41°C
55°C
68°C
81°C
1.5
(
23°C
Change with
10.
d
to confirm.
Note
Setting the heating curve slope or level
too high or too low will not result in dam-
age to your heating system.
For technically-minded system users
■ Heating curves illustrate the relation-
ship between the outside temperature
and the flow temperature. Simplified:
The lower the outside temperature, the
higher the flow temperature.
The illustrated heating curves apply with
the following settings:
■ Heating curve level = 0
Different level settings shift the curve
in parallel in a vertical direction.
■ Standard room temperature = approx.
20 °C
In the delivered condition, the slope is
set to 1.4; the level to 0.
Central heating
Changing the heating curve
(cont.)
5549 811 GB