4
If the heating system develops a fault
Danger
Fault messages indicate faults in
the heating system. If faults are not
rectified, they can have life threat-
ening consequences.
Do not acknowledge fault mes-
sages several times in quick suc-
cession. Inform your heating con-
tractor so the cause can be ana-
lysed and the fault rectified.
Conditions for siting
Danger
Sealed vents result in a lack of
combustion air. This leads to incom-
plete combustion and the formation
of life threatening carbon monoxide.
Never cover or close existing vents.
Do not make any subsequent modi-
fications to the building characteris-
tics that could affect safe operation
(e.g. cable/pipework routing, clad-
ding or partitions).
Danger
Easily flammable liquids and mate-
rials e.g. naphtha/petrol, solvents,
cleaning agents, paints or paper,
can trigger deflagration and fire.
Never store easily flammable sub-
stances in the boiler room or in
direct proximity to the heating sys-
tem.
!
Please note
Incorrect ambient conditions can
lead to heating system damage and
can put safe operation at risk.
■
Ensure ambient temperatures are
above 0 °C and below 35 °C.
■
Prevent air contamination by halo-
genated hydrocarbons (e.g. as
contained in paints, solvents or
cleaning fluids) and excessive
dust (e.g. through grinding/polish-
ing work).
■
Avoid continuously high humidity
levels (e.g. through continuous
drying of washing).
Extractors
The operation of appliances that extract
air to the outside (cooker hoods, extrac-
tors, air conditioning units, etc.) can cre-
ate negative pressure. If the boiler is
operated at the same time, this can lead
to a reverse flow of flue gas.
Danger
The simultaneous operation of the
boiler and appliances that extract
air to the outside can result in life
threatening poisoning due to a
reverse flow of flue gas.
Take suitable steps to ensure an
adequate supply of combustion air.
If necessary, contact your heating
contractor.
Safety instructions
For your safety
(cont.)
5679252
Содержание VITOLIGNO 300-H Series
Страница 42: ...42 2 for Fault 3 d to confirm Checks Checking fault messages cont 5679252...
Страница 67: ...67 5679252...