49
Troubleshooting
Strapping plug configuration and coding
Strapping plug configuration on circuit boardĂVRĂ20
Strapping plugĂ"X
Ă
6"
As delivered condition without
function "External burner blocking".
Including "External burner blocking"
function (only if the contact on
plugĂ"X
Ă
6.1
Ă
Ć
Ă
X
Ă
6.2" is connected).
Strapping plugsĂ"X
Ă
2"
Ă
Ć
Ă
"X
Ă
4"
As delivered condition without
extension module Viessmann 2Ćwire
BUS:
Two strapping plugs installed as
shown.
With extension module Viessmann
2Ćwire BUS:
Both strapping plugs removed.
External demand
(on site)
With standard programming unit
Change coding addressĂ"30:00" to
"30:01" and "35:00" to "35:01".
With Comfortrol programming unit
Change coding addressĂ"011:000" to
"011:001" and "027:000" to
"027:001".
Please note:
The boiler is started according to the
setting of coding addressĂ"125"
(standard programming unit) or "0C5"
(Comfortrol programming unit).
The boiler water temperature is
maintained according to the setting
of coding addressĂ"102" (standard
programming unit) or "0A2"
(Comfortrol programming unit).
5692Ă485
G
B
Содержание Vitodens 200
Страница 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Страница 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Страница 99: ...101 5692Ă485ĂGB ...
Страница 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Страница 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Страница 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...