Vitodens 200-W B2HE Operating

6167 814 - 01

46

Appendix

Terminology 

(continued)

Heating circuit

A heating circuit is a sealed unvented circuit connecting

the boiler and the radiators, in which the heating water 

circulates.

A system may comprise several heating circuits.

For example, one heating circuit for the rooms occupied

by you and one heating circuit for the rooms of a separate 

apartment.

The heating circuits are designated at the factory as

“Heating circuit 1”, “Heating circuit 2”, etc.

If you or your qualified contractor have renamed the

heating circuits, e.g. as “Apartment”, that name will be

displayed instead of “Heating circuit ...”.

Heating circuit pump

Circulation pump for circulating the heating water in the 

heating circuit

Mixing valve

Hot heating water from the boiler is mixed with cooled 

heating water from the heating circuit. The heating water, 

brought to the right temperature as required, is pumped to 

the heating circuit by the heating circuit pump.

To ensure the required target room temperature is achieved,

the control unit adjusts the supply temperature via the 

mixing valve to suit different conditions.

Night setback

See “Reduced heating operation”

Room air dependent operation

The combustion air is drawn from the room where the

boiler is installed.

Direct vent operation

Combustion air is drawn from outside the building.

Room temperature

 Standard room temperature or comfort room  

 

 temperature:

  Set the standard room temperature or comfort room

  temperature for periods when you are at home during

 the 

day.

 Reduced room temperature:

  For periods when you will be absent or during the night,  

  set the reduced room temperature; see “Heating

 operation”.

Return temperature

The return temperature is the temperature at which the

heating water leaves a system component such as a

heating circuit.

Safety valve

Safety equipment that must be installed in the cold water 

pipe by your contractor. The safety valve opens

automatically to prevent excess pressure in the DHW tank.

The heating circuits are also equipped with safety valves.

Solar circuit pump

In conjunction with solar thermal systems. The solar 

circuit pump delivers the cooled heat transfer medium 

from the DHW cylinder indirect coil to the solar collectors.

Temperature target

See “Target temperature”.

Summer mode

In warmer months, you can switch off heating operation.

To do so, select “DHW” operating program “On” and

“Standby mode”.

The system remains in operation for DHW heating. 

Central heating is switched off.

Storage tank loading pump

Circulation pump for heating the DHW in the DHW tank.

Target temperature

Specified temperature that should be reached, 

e.g. target DHW temperature.

Drinking water filter

A device that removes solids from potable water. 

The drinking water filter is installed in the cold water 

pipe upstream of the DHW cylinder or the instantaneous

water heater.

Supply temperature

The supply temperature is the temperature at which the 

heating water enters a system component such as a 

heating circuit.

Weather-compensated operation

See “Heating operation”

Time program

In the time programs you determine what your heating

system should do at what time.

Operating status

The operating status indicates how a component of

your heating system is being operated.

For example, the operating statuses for central heating

have different temperature levels.

The times for the operating status changeover are defined 

when the time program is set.

DHW recirculation pump

The DHW recirculation pump transports the DHW around 

a loop line between the DHW tank and the draw-off 

points (e.g. hot tap). This ensures that hot water is rapidly 

available at the draw-off points.

Содержание VITODENS 200-W B2HE 199

Страница 1: ...e fire department Installation and service must be performed by a qualified installer service agency or the gas supplier If the information in this manual is not followed exactly a fire or explosion m...

Страница 2: ...ating season begins Carbon monoxide Improper installation adjustment service and or maintenance can cause flue products to flow into living space Flue products contain poisonous carbon monoxide gas Fo...

Страница 3: ...mfort 10 Operating Principles 11 Screen Displays 11 Buttons and Symbols 12 Overview of the Main menu 13 Operating Program 14 Heating Circuit or Continuous Operation Default Display 15 DHW Default Disp...

Страница 4: ...28 Automatic Summertime Wintertime Changeover 28 Setting the Language 28 Setting Units 28 Entering the Contractor s Contact Details 29 Setting the Home Screen 29 Changing the Colorific Value or Correc...

Страница 5: ...our heating contractor should always perform the initial start up and explain the system Any warranty is null and void if these instructions are not followed Working on the equipment All personnel wor...

Страница 6: ...ilation air and no chemicals garbage gasoline combustible materials flammable vapors and liquids are stored not even temporarily in the vicinity of the boiler Do not allow unsupervised children near t...

Страница 7: ...only be performed by a qualified heating contractor IMPORTANT Installation area conditions Ensure ambient temperatures are higher than 32 F 0 C and lower than 95 F 35 C Prevent the air from becoming c...

Страница 8: ...an be operated with the control unit The temperature shown on the display is the boiler water temperature In constant operation the boiler provides heating water with a constant supply temperature reg...

Страница 9: ...protection Your boiler and DHW tank if installed are protected against frost Wintertime summertime changeover This changeover is automatic Date and time The date and time were set by your heating cont...

Страница 10: ...g away select the Holiday program During the period that you are away the room temperature will be reduced and DHW heating switched off More comfort in your home Set your individual preferred temperat...

Страница 11: ...an switch off the Lightguide See page 27 Home screen The default displays provide access to the most important settings and checks Use to choose between the following displays Heating circuit or Conti...

Страница 12: ...n area C Note The buttons and symbols available depend on the operating mode Weather compensated operation or constant operation Takes you back to the home screen Takes you one step back in the menu o...

Страница 13: ...or more central heating settings e g target temperature values Further information See page 15 Test mode For contractors only Further information See page 35 DHW For DHW heating settings e g for the D...

Страница 14: ...ting Frost protection for the boiler is active DHW heating Note Not valid for systems with a DHW tank with temperature switch such as an Aquastat DHW ON DHW is heated in accordance with the DHW temper...

Страница 15: ...nuous operation default display you can adjust and check the most frequently used settings Raises the room temperature value in weather compensated operation Raises the supply temperature value in con...

Страница 16: ...Dashboard default display for cascade control This display shows the lead boiler in the cascade its current supply temperature the target supply temperature and the modulation level Note All informat...

Страница 17: ...a Solar energy yield Solar energy bar chart See the following chapter Total solar energy generated Solar circuit pump operating time Solar circuit pump operating state Reheating suppression Solar stag...

Страница 18: ...ter in the DHW tank is heated to the target DHW temperature DHW heating is switched off DHW recirculation pump The DHW recirculation pump is switched on The DHW recirculation pump is switched off The...

Страница 19: ...to confirm 9 to quit the time program Deleting time phases The procedure is explained using the example of central heating for heating circuit 1 in weather compensated operation Example For Monday yo...

Страница 20: ...option is not available Tap the following buttons 1 If applicable for the Heating circuit default display 2 Heating circuit 1 in the menu bar 3 Required heating circuit Factory settings for the temper...

Страница 21: ...7 to confirm Note Extensive information on adjusting the Heating curve can be found in chapter Terminology in the appendix Temporarily Adjusting the Room Temperature for Certain Heating Circuits Switc...

Страница 22: ...time phase becomes active DHW heating is active The Holidays at home function starts and ends according to the set times for the start date and end date Only valid for heating circuits Note As long as...

Страница 23: ...ng commissioning the holiday program is switched on for all heating circuits If Apartment building was selected by your contractor during commissioning DHW heating will only be switched off if all hea...

Страница 24: ...ighlighted button or 3 ON if you want to start DHW heating OFF if you want to stop DHW heating For information on the operating programs See page 14 One Off DHW Heating Outside the Time Program Note N...

Страница 25: ...e required day or every day The selection is highlighted 6 to confirm Switching off increased DHW hygiene Tap the following buttons 1 2 DHW 3 Hygiene function 4 Deselect the highlighted day or every d...

Страница 26: ...following buttons 1 Any on screen button Panel locked is displayed 2 Do you want to unlock the operation is displayed 3 An entry field and keyboard appear 4 Enter the password viessmann or the passwo...

Страница 27: ...he following buttons 1 2 Settings 3 Rename heating circuits 4 Required heating circuit e g Heating circuit 1 5 Type in the required name e g Ground floor 1 to 20 characters 6 to confirm The name assig...

Страница 28: ...ng the Language Setting Units The Time and Date are set at the factory If your system has been shut down for a prolonged period you may need to reset the Time and Date Tap the following buttons 1 2 Se...

Страница 29: ...s 1 2 Settings 3 Selecting the default display 4 Required display 5 to confirm Note Tap to call up the selected home screen Switching WiFi on or off Tap the following buttons 1 2 Settings 3 Internet 4...

Страница 30: ...tings if necessary Establishing a WiFi connection Note Prerequisite WiFi is switched on Tap the following buttons 1 2 Settings 3 Internet 4 Network selection Available WiFi networks are displayed Note...

Страница 31: ...ndard room temperature or standard supply temperature Reduced room temperature or reduced supply temperature Operating program DHW temperature Time program for DHW heating Time program for DHW recircu...

Страница 32: ...etails Internet Open source licence Cascade Cascade boilers Calls up the licence for the programming unit Note If names have been given to the heating circuits or heating zones the allocated name is s...

Страница 33: ...ed in this product is distributed WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE The single licences may contain more details on a limita...

Страница 34: ...rner fault If the burner is locked due to a fault you can reset the burner Tap the following buttons 1 A further prompt is displayed 2 Reset 3 to confirm The burner is reset and will restart If your s...

Страница 35: ...onding messages Status Warnings Information Faults Service messages Note You can only activate emissions test mode in the service menu Emissions test mode for testing flue gas must only be activated b...

Страница 36: ...t are briefly started every 24 hours to prevent them from seizing up The diverter valves are switched over at regular intervals Ask your contractor about the following Required system pressure Positio...

Страница 37: ...ll be able to analyze the cause and rectify the fault Cause Remedy The boiler is switched off Turn on the ON OFF switch See page 36 Switch on the power supply to your system e g at a separate MCB fuse...

Страница 38: ...rating program See page 14 Room temperature supply temperature See page 20 Time See page 28 Time program for central heating See page 18 The vacation program is switched on See page 23 No fuel Open th...

Страница 39: ...me For this observe the manufacturer s instructions Safety valve DHW tank The function of the safety valve must be checked every six months by the user or a contractor through venting see valve manufa...

Страница 40: ...Heating curve Additional heating circuits As for Heating circuit 1 Heating zones Supply temperature or heating curve DHW Note Not valid for systems with a DHW tank with temperature switch such as an...

Страница 41: ...nction heating zone 1 2 3 Altitude Heating zones 1 to 4 Status Pump Heating curve slope with weather compensated operation Heating curve level with weather compensated operation Supply temperature Hea...

Страница 42: ...switch Burner Burner Burner hours run Burner starts Burner modulation Supply temperature Flue gas temperature Flow rate in L h Status of external blocking Contractor contact details Internet Manufactu...

Страница 43: ...Return temperature heating circuit Solar 3 way valve position Solar central heating backup TS3 DHW preheating temperature Holiday program Note This can be selected only if Apartment building was selec...

Страница 44: ...ture level using the time program for central heating Room temperature dependent heating operation In room temperature dependent operation a room is heated until the set room temperature has been reac...

Страница 45: ...g curve level 0 Standard room temperature target room temperature 68 F 20 C Note Setting the slope or shift too high or too low will not cause any damage to your heating system Both settings affect th...

Страница 46: ...ure at which the heating water leaves a system component such as a heating circuit Safety valve Safety equipment that must be installed in the cold water pipe by your contractor The safety valve opens...

Страница 47: ...ce or attempted repair may result in a fire or explosion D Do not use this boiler if any part has been under water Immediately call a qualified service technician to inspect the boiler and to replace...

Страница 48: ...echnical information subject to change without notice Printed on environmentally friendly recycled and recyclable paper 6167 814 01 Vitodens 200 W B2HE Operating Scan for digital copy of this document...

Отзывы: