Checking the flue system for unrestricted flow and tightness
Checking the firm seating of electrical connections
Checking all gas equipment for tightness at operating pressure
Danger
Escaping gas leads to a risk of explosion.
Check all gas equipment for tightness.
!
Please note
The use of leak detection spray can result in
faulty operation.
Leak detection spray must not come into contact
with electrical contacts or block the diaphragm
opening on the gas valve.
Fitting the front panel
2x
1.
2.
Fig. 30
1.
Hook the front panel into place.
2.
Tighten screws on the underside of the boiler.
Setting display backlighting for standby
0
1.
Turn ON the ON/OFF switch.
0
2.
Tap
MODE
.
0
3.
/ until
CONFI
flashes.
Commissioning, inspection, maintenance
Checking all connections on the heating water and DHW sides for leaks