Fault Diagnosis and Correction

Issue

Cause

Corrective Action

Heating system does not start up

Heating system switch turned to OFF on
control unit

Turn switch to ON on control unit.

Selector dial “

tr

” is set to “

9

“.

Set required heating water temperature
(see page 10).

Circuit breaker or fuse in power
supply or in boiler control unit has blown
or tripped

Inform heating contractor.

Burner does not switch on or only
intermittently

No gas

Open gas shut-off valve or contact your
gas supply company.

y

Fault on control unit

Make a note of the fault code and in-
form heating contractor.

Burner does not start up; red burner fault
lamp ”

U

” is lit on control unit

Faulty start-up

Press burner fault reset button (see
page 8). Should this attempt fail,
contact your heating contractor.

Low water level

System operating pressure is flashing on
the display. Inform heating contractor.

Burner does not start up; burner fault lamp

U

” appears in display

Power supply too low

Contact your Hydro company.

The burner switches off even though
the desired room temperature has not

Fault in combustion air supply or in the
venting system

Contact your heating contractor.

p

been reached

Heating water temperature or room tem-
perature is set too low

Increase heating water temperature by
turning selector dial “

tr

” or by

increasing desired room temperature on
the room thermostat.

Rooms are cold although burner is
operating

Domestic hot water supply has
priority (operation with DHW storage
tank only)

Wait until the domestic hot water heat-
ing is complete.

Fault on programmable room
thermostat

Contact your heating contractor.

Fault Messages on the Display

Any faults in your heating system are
indicated on the display by a flashing fault
symbol “

U

“.

Read off the fault code in the display and
report it to your heating contractor. This
helps the contractor to properly prepare,
and may result in lower service costs.

Warning

Visually inspect the vent termination for any signs of blockage. Under cold climate conditions (sustained temperatures below 0°F /
-18°C) the vent termination may be severely blocked by icicle and frost build-up. The boiler control will automatically shut down the
boiler should air intake or vent be blocked. Remove blockage if possible. Reset the boiler and the boiler should attempt to restart. If
blockage is not obvious and cannot be removed, contact a licensed professional heating contractor.

5581

532

v1.1

Содержание Vitodens 100-W WB1A Series

Страница 1: ...asoline or other flammable liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances Do not touch any electrical switches do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and se...

Страница 2: ...d Important Regulatory and Installation Requirements in the Installation Instructions H Advice to owner Once the installation work is complete the heating contractor must familiarize the system operator ultimate owner with all equipment as well as safety precautions requirements shut down procedure and the need for professional service annually before the heating season begins H Carbon monoxide Im...

Страница 3: ... Heating System 10 Heating System Operation 10 DHW Production 10 Heating Water Temperature and System Pressure 11 Switching OFF Vitodens with Frost Protection 12 Shutting Down the Heating System 12 Information Fault Diagnosis and Correction 13 Fault Messages on the Display 13 Service Instructions for your Heating System 14 How to Save Energy 15 Lighting and Operating Instructions 16 5581 532 v1 1 ...

Страница 4: ...ing system and all external controls have been deactivated Close main gas supply valve Take precautions in all instances to avoid accidental activation of power during service work H Maintenance and cleaning Regular inspection and service by a qualified heating contractor is important to the performance of the Viessmann Vitodens 100 W Neglected maintenance impacts on warranty regular inspection en...

Страница 5: ...and no chemicals garbage gasoline combustible materials flammable vapors and liquids are stored not even temporarily in the vicinity of the boiler Do not allow unsupervised children near the boiler Service inspection of the boiler and the system is recommended once per year Maintenance service and cleaning are specified in the Installation and Service Instructions Before the heating season begins ...

Страница 6: ...ected areas as quickly as possible to prevent mold from developing If your home will be unattended for an extended period of time during cold weather you should H Shut off the water supply to the building drain the water pipes and add an antifreeze for potable water to drain traps and toilet tanks Open faucets where appropriate Or H Have someone check the building frequently during cold weather an...

Страница 7: ...ls H Remodelling areas hobby rooms H Garages with workshops H Furniture refinishing areas H Dry cleaning laundry areas and establishments H Auto body shops H Refrigeration repair shops H Metal fabrication plants H Plastic manufacturing plants H Photo processing plants H Beauty salons Products containing contaminants H Chlorine type bleaches detergents and cleaning solvents found in household laund...

Страница 8: ...D display Opening the control unit Controls and indicators are located behind the hinged front cover Control and display elements The control unit is preset at the factory for standard operation Your heating system is ready for use The factory presets may be individually adjusted to suit your specific requirements 5581 532 v1 1 tr 9 ...

Страница 9: ...ature controller thermostat is installed the desired room temperature will be adjusted using this device Make adjustments using the appropriate operating instructions only Please also note lf thermostatic radiator valves are installed in the room where the control is installed they must be fully open In case the room temperature setting on the separate room temperature controller is not sufficient...

Страница 10: ...oiler supply piping Minimum system pressure is 14 psig Please contact your heating contractor if the system pressure is too low 3 Open gas shutoff valve Heating System Operation tr 9 Switching ON Turn the selector dial tr to the desired boiler water temperature The display r indicates when room temperature has been reached Switching OFF Turn the selector dial tr to 9 Please note If an external dev...

Страница 11: ...displayed Checking the system pressure 1 Turn the selector dial tr fully counter clockwise towards 9 The display now shows the current system pressure e g 20 psig 2 Return the selection dial back to its original position Note The display will flash if the system pressure falls below 8 psig In this instance please contact your heating contractor 5581 532 v1 1 psi ...

Страница 12: ...ting System Shut down your heating system completely if it is not needed for longer periods of time several months Before you switch your heating system OFF for longer periods it is advisable to contact your local heating contractor Your heating professional will take any necessary measures e g for freeze protection of the system or to protect the heat emitter surfaces e g radiators etc 1 Close ga...

Страница 13: ...he venting system Contact your heating contractor p been reached Heating water temperature or room tem perature is set too low Increase heating water temperature by turning selector dial tr or by increasing desired room temperature on the room thermostat Rooms are cold although burner is operating Domestic hot water supply has priority operation with DHW storage tank only Wait until the domestic h...

Страница 14: ...ce within 2 years of initial start up and every 2 years thereafter Cleaning of the inside surfaces of the domestic hot water storage tank including domestic hot water connections may only be performed by an licensed professional heating contractor Vitocell 100 Viessmann recommends an annual inspection and replacement if required of the consumable anode by a licensed professional heating contractor...

Страница 15: ...control unit 4 supplied by others e g normal room temperature alternating with reduced room temperature H Set the domestic hot water temperature of the DHW tank 5 on the control unit of the tank or on external controller H Control your consumption of hot water A shower generally consumes less energy than a bath with regular maintenance Regular maintenance check ups of your heating system by a lice...

Страница 16: ... explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above on this label 2 Set thermostat or other operating control to lowest setting 3 Turn off all electric power to the applianc...

Страница 17: ...17 5581 532 v1 1 ...

Страница 18: ...18 5581 532 v1 1 ...

Страница 19: ...19 5581 532 v1 1 ...

Страница 20: ...il viessmann us com 20 Quick Reference C F 40 40 35 31 25 13 20 4 18 0 16 3 14 7 12 10 10 14 9 16 8 18 7 19 6 21 5 23 4 25 3 27 2 28 1 30 0 32 1 34 2 36 3 37 4 39 5 41 6 43 7 45 8 46 9 48 10 50 12 54 14 57 16 61 18 64 20 68 25 77 30 86 35 95 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 Printed on environmentally friendly recycled and recyclable paper 5581 532 v1 1 Technical informatio...

Отзывы: