Fault Diagnosis and Correction
Issue
Cause
Corrective Action
Heating system does not start up
Heating system switch turned to OFF on
control unit
Turn switch to ON on control unit.
Selector dial “
tr
” is set to “
9
“.
Set required heating water temperature
(see page 10).
Circuit breaker or fuse in power
supply or in boiler control unit has blown
or tripped
Inform heating contractor.
Burner does not switch on or only
intermittently
No gas
Open gas shut-off valve or contact your
gas supply company.
y
Fault on control unit
Make a note of the fault code and in-
form heating contractor.
Burner does not start up; red burner fault
lamp ”
U
” is lit on control unit
Faulty start-up
Press burner fault reset button (see
page 8). Should this attempt fail,
contact your heating contractor.
Low water level
System operating pressure is flashing on
the display. Inform heating contractor.
Burner does not start up; burner fault lamp
”
U
” appears in display
Power supply too low
Contact your Hydro company.
The burner switches off even though
the desired room temperature has not
Fault in combustion air supply or in the
venting system
Contact your heating contractor.
p
been reached
Heating water temperature or room tem-
perature is set too low
Increase heating water temperature by
turning selector dial “
tr
” or by
increasing desired room temperature on
the room thermostat.
Rooms are cold although burner is
operating
Domestic hot water supply has
priority (operation with DHW storage
tank only)
Wait until the domestic hot water heat-
ing is complete.
Fault on programmable room
thermostat
Contact your heating contractor.
Fault Messages on the Display
Any faults in your heating system are
indicated on the display by a flashing fault
symbol “
U
“.
Read off the fault code in the display and
report it to your heating contractor. This
helps the contractor to properly prepare,
and may result in lower service costs.
Warning
Visually inspect the vent termination for any signs of blockage. Under cold climate conditions (sustained temperatures below 0°F /
-18°C) the vent termination may be severely blocked by icicle and frost build-up. The boiler control will automatically shut down the
boiler should air intake or vent be blocked. Remove blockage if possible. Reset the boiler and the boiler should attempt to restart. If
blockage is not obvious and cannot be removed, contact a licensed professional heating contractor.
5581
532
v1.1