Vertical Vent Installation (Coaxial)
31
Vent Length Requirements
(continued)
Maximum vent length with increasers
Table 16. Maximum vent length for
vertical installations (Vitodens 100-W)
Model
No.
WB1A 8-24, 8-30
System
vent size
80/125
*1
100/150
*2
Max.
vent
length
39.4 ft.
12 m
46 ft.
14 m
*1
If used with increasers 60/100 to
80/125.
*2
If used with increasers 60/100 to
100/150
Table 17. Maximum vent length for
vertical installations (Vitodens 200-W)
Model
No.
WB2
6-24C,
6-24
WB2 8-32
System
vent size
100/150
*1
100/150
*1
Max.
vent
length (a)
39.4 ft.
12 m
33 ft.
10 m
*1
If used with increasers 80/125 to
100/150.
Minimum vent length
The minimum equivalent vertical vent
length for all models is 4 ft./1.2 m
(=length of vent termination).
5
2
8
5
2
6
8
v
3
.8
a
Coaxial increaser
for system 60/100 to 100/150
Coaxial increaser
for system 60/100 to 80/125
Vitodens 100-W, WB1A
Models 8-24, 8-30
a
Coaxial increaser
for system 80/125 to 100/150
Vitodens 200-W, WB2
Models 6-24C, 6-24, 8-32