![Viessmann Vitocell 300 EHA Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/viessmann/vitocell-300-eha-series/vitocell-300-eha-series_installation-instructions-manual_1018596011.webp)
Set-up
11
Multiple Tank Set-up
only for 92 and 120 USG / 350 and 450 ltr capacity
Two
tanks, each with
92 USG / 350 ltr content,
and up to
three tanks
, each with
120 USG / 450 ltr content
, may be stacked vertically.
1.
Set-up and orient lower tank in its
final location.
2.
Remove levelling bolts of top tank.
3.
Carefully unhook front panel.
4.
Remove insulation.
5.
Remove spring clip and carefully pull
sensor of the thermometer out of
tank cap.
6.
Pull side panels of top tank forward
to remove.
1.
Place top tank on top of bottom tank
and align.
2.
Take packaged M 8 bolts, drop in
holes of top tank support brackets
and fasten to bottom tank support
brackets.
3.
Reinstall side panels.
Install third tank (if applicable) in an
identical fashion as the second tank.
4.
Fully insert sensor into opening in
tank cap and secure using spring-clip.
5.
Install insulation.
6.
Install front panel.
5167
535
v1
.2
2.
6.
3.
4.
6.
5.
M 8
1.
2.
3.
5.
6.
4.
Fig 6.
Installing tanks in a stacked fashion