73
Enable instantaneous heating water heater for DHW heating
Parameter
Setting
"DHW"
Ó
"Enable electric heaters for DHW heating 6015"
"1"
Parameters for external heat generators
Parameter
Setting
"External heat source"
Ó
"Enable external heat source 7B00"
"1"
Enable external heat source for DHW heating
Parameter
Setting
"External heat source"
Ó
"Enable external heat source for DHW heating 7B0D"
"1"
Control strategy
Parameter
Setting
"External heat source"
Ó
"Fuel 7B7F"
"1"
Gas
"2"
Oil
"Appliance control strategy 7BE1"
"0"
Economical
"1"
Ecological
"2"
Fixed temperature limits
Primary energy factors for ecological control strategy ("Appliance control strategy 7BE1" set to "1")
Parameter
Setting
"External heat source"
Ó
"Primary energy factor, electricity 7BE4"
"1"
to
"32767"
(
≙
0.01 to 327.67)
"Primary energy factor, fossil 7BE5"
"1"
to
"32767"
(
≙
0.01 to 327.67)
Energy prices for economical control strategy ("Appliance control strategy 7BE1" set to "0")
Parameter
Setting
"External heat source"
Ó
"Electr. price, standard tariff 7BE8"
"1"
to
"32767"
(
≙
0.01 to
327.67 ct/kWh)
"Electr. price, premium tariff 7BE9"
"1"
to
"32767"
(
≙
0.01 to
327.67 ct/kWh)
"Electricity price, low tariff 7BEA"
"1"
to
"32767"
(
≙
0.01 to
327.67 ct/kWh)
"7BEB Fossil fuel price, standard tariff"
"1"
to
"32767"
(
≙
0.01 to
327.67 ct/kWh)
Parameters for immersion heater
Parameters
Setting
"DHW"
Ó
"Enable electric heaters for DHW heating 6015"
"1"
"Enable booster heaters for DHW heating 6014"
"1"
Commissioning, inspection, maintenance
Commissioning the system
(cont.)
6150148