104
Type AWO-M/AWO-M-E/AWO-M-E-AC
201.A04
201.A06
201.A08
201.A10
201.A13
201.A16
Air intake temperature
Cooling mode (type
AWO-M-E-AC only)
■
Min.
°C
10
10
10
10
10
10
■
Max.
°C
45
45
45
45
45
45
Heating mode
■
Min.
°C
–
20
–
20
–
20
–
20
–
20
–
20
■
Max.
°C
35
35
35
35
35
35
Heating water
(secondary cir-
cuit)
Minimum flow rate
l/h
700
700
700
1400
1400
1400
Minimum volume in the heating
system, cannot be fitted with
shut-off devices
l
50
50
50
50
50
50
Max. external pressure drop
(RFH) at minimum flow rate
mbar
705
705
705
500
500
500
kPa
70.5
70.5
70.5
50
50
50
Max. flow temperature
°C
60
60
60
60
60
60
Outdoor unit electrical values
Rated voltage, compressor
1/N/PE 230 V/50 Hz
Max. operating current, com-
pressor
A
13.0
14.6
14.6
19.9
23.3
23.3
Cos
φ
0.99
0.99
0.99
0.99
0.99
0.99
Starting current, compressor
A
15
15
15
15
15
15
Fuse rating
B16A
B16A
B16A
B25A
B25A
B25A
IP rating
IPX4
IPX4
IPX4
IPX4
IPX4
IPX4
Indoor unit electrical values
Heat pump control unit/PCB
■
Rated voltage, control
unit/PCB
1/N/PE 230 V/50 Hz
■
Power supply fuse rating
1 x B16A 1 x B16A 1 x B16A 1 x B16A 1 x B16A
1 x B16A
■
Internal fuse
6.3 A (slow)/250 V
Instantaneous heating water
heater
■
Type AWO-M-E/AWO-M-E-AC:
Factory-fitted
■
Type AWO-M: Accessories
■
Rated voltage
1/N/PE 230 V/50 Hz
or
3/N/PE 400 V/50 Hz
■
Heating output
kW
9
9
9
9
9
9
■
Power supply fuse rating
3 x B16A 3 x B16A 3 x B16A 3 x B16A 3 x B16A
3 x B16A
Specification
Specification
(cont.)
6150148