20
Floorstanding installation with support: Line entry
above ground level
3000
A
200
300
K
702
835
E
F
1100
C D
200
L
B
G
H
500
180
Fig. 11
A
Ground
B
Pathway, patio
C
Hydraulic connection lines, indoor/outdoor unit
D
Indoor/outdoor unit Modbus cable and outdoor unit
power cable:
Route the cables so they are not stressed.
E
Openings in the base plate for free drainage of
condensate:
Never seal the openings.
F
Connection set, wall mounting (accessories)
G
Support for floorstanding installation (accessories)
H
Foundation strip
K
Frost protection for foundations (compacted
crushed stone, e.g. 0 to 32/56 mm); thickness of
layer subject to local requirements and building
regulations
L
Flexible separating layer between the foundations
and the building
Note
Provide thermal insulation of sufficient thickness on the
pipework to the outdoor air: See table on page 13.
Floorstanding installation with support and design
casing: Line entry above ground level
3000
200
200
H
340
A
B
300
550
800
410
K
L
E
M
300
180
F
C D
G
Fig. 12
A
Ground
B
Pathway, patio
C
Hydraulic connection lines, indoor/outdoor unit
D
Indoor/outdoor unit Modbus cable and outdoor unit
power cable:
Route the cables free of stress.
E
Openings in the base plate for free drainage of
condensate:
Never seal the openings.
F
Connection set, wall mounting (accessories)
G
Design casing wall connection (accessories)
H
Design casing with support (accessories)
K
Foundation strip
L
Frost protection for foundations (compacted
crushed stone, e.g. 0 to 32/56 mm); thickness of
layer subject to local requirements and building
regulations
M
Flexible separating layer between the foundations
and the building
Note
Provide thermal insulation of sufficient thickness on the
pipework to the outdoor air: See table on page 13.
Installation sequence
Installing the outdoor unit
(cont.)
6150148
Installation