Cylinder capacity
l
160
200
300
500
750
1000
Length (
7
)
– Incl. thermal insulation
a
mm
581
581
633
859
960
1060
– Excl. thermal insulation
mm
—
—
—
650
750
850
Width
– Incl. thermal insulation
b
mm
608
608
705
923
1045
1145
– Excl. thermal insulation
mm
—
—
—
837
947
1047
Height
– Incl. thermal insulation
c
mm
1189
1409
1746
1948
2106
2166
– Excl. thermal insulation
mm
—
—
—
1844
2005
2060
Height when tilted
– Incl. thermal insulation
mm
1260
1460
1792
—
—
—
– Excl. thermal insulation
mm
—
—
—
1860
2050
2100
Installation height
mm
—
—
—
2045
2190
2250
Weight
incl. thermal insulation
kg
86
97
151
181
295
367
Heating water capacity
l
5.5
5.5
10.0
12.5
24.5
26.8
Heating surface
m
2
1.0
1.0
1.5
1.9
3.7
4.0
Connections
(male thread)
Heating water flow and return
R
1
1
1
1
1¼
1¼
Cold water, DHW
R
¾
¾
1
1¼
1¼
1¼
DHW circulation
R
¾
¾
1
1
1¼
1¼
Information regarding continuous output
When engineering systems with the specified or calculated continuous
output, select a matching circulation pump. The stated continuous out-
put is only achieved when the rated boiler heating output is ≥ the con-
tinuous output.
160 and 200 litre capacity
SPR
b
a
c
d
e
f
g
h
k
b
VA
WW
Z
HV/SPR
HR
BÖ
KW/E
BÖ
Inspection and cleaning aperture
E
Drain
HR
Heating water return
HV
Heating water flow
KW
Cold water
SPR Cylinder temperature sensor of the cylinder temperature con-
troller or thermostat
VA
Protective magnesium anode
WW DHW
Z
DHW circulation
DHW cylinder
(cont.)
38
PYROMAT ECO
6
5822 546 GB
Содержание PYROMAT ECO
Страница 62: ...62 PYROMAT ECO ...
Страница 63: ...PYROMAT ECO 63 5822 546 GB ...