3
Handling
3.1
Assembly information
3.1.1
Mounting conditions
The power pack should be mounted in an easily accessible place to
allow subsequent access.
Before beginning to clad, a concealed socket should be installed for the
power pack with empty pipe to the cistern (installation set
If necessary, the power pack cable can be extended to a length of
4.75 metres (two extension cables
„Optional accessories“ on page 9
X1
X2
X3
Fig. 2: Installation position of the power pack
X1 max. 0.75 m
X2 max. 2.75 m with an extension cable (article number 628 505)
X3 max. 4.75 m with two extension cables (article number 628 505)
An extension of the mains supply by more than 5 metres
can lead to a situation in which the power is not sufficient
to actuate the flush.
Protected zone
Installation position of the power pack
Handling
Electronics accessory set