Masonry and concreted walls

When mounting multiple washbasin elements with an

interval of > 500 mm, Viega recommends to use a Pre‐

vista Dry support bracket (model 8570.48). Observe the

instructions for use of the support bracket when

mounting.

Handling

Prevista Dry washbasin element with concealed connection box

12

Содержание 8535.33

Страница 1: ...Instructions for Use Prevista Dry washbasin element with concealed connection box for WB with single hole fitting Model Year built from 8535 33 03 2019 INT...

Страница 2: ...e 5 2 3 Product description 6 2 3 1 Overview 6 2 3 2 Compatible components 6 2 3 3 Technical data 7 2 4 Accessories 8 3 Handling 9 3 1 Assembly information 9 3 1 1 Mounting conditions 9 3 1 2 Installa...

Страница 3: ...to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes War...

Страница 4: ...g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national law...

Страница 5: ...EN 1996 1 1 Suitable concreted walls DIN 1045 Suitable support profiles DIN 18183 2 2 Intended use 2 2 1 Areas of use The Prevista Dry washbasin element is suitable for mounting on masonry wall const...

Страница 6: ...the floor 6 Screws for fixing in support profile 7 site protection for concealed connection box 8 drain elbow 9 pipe elbows 10 compression fittings 11 Cover plate 12 threaded rods for fixing sanitary...

Страница 7: ...in elbow outlet side DN 40 50 Rubber nipple DN 50 30 Hole diameter for fixing in wooden frame construction 11 mm Construction height 1120 mm Product information Prevista Dry washbasin element with con...

Страница 8: ...ting directly onto the installation body or corner mounting on masonry or metal support profile Prevista Dry fixing set model 8573 for single mounting of Prevista Dry elements to the solid wall Previs...

Страница 9: ...comply with the regulations in section Regulations from section Fields of application Mounting condi tions on page 5 The washbasin element may only be mounted on even wall surfaces With the constructi...

Страница 10: ...llation dimensions NBY 3 2 Assembly 3 2 1 Mounting the element Seal the corner valve e g using hemp Preparing the concealed connection box Handling Prevista Dry washbasin element with concealed connec...

Страница 11: ...the additional markings when aligning the corner valves Screw in until the connection to the washbasin fitting is between the markings Mount the entire seats in the concealed connection box The object...

Страница 12: ...basin elements with an interval of 500 mm Viega recommends to use a Pre vista Dry support bracket model 8570 48 Observe the instructions for use of the support bracket when mounting Handling Prevista...

Страница 13: ...the fixing points on the floor n X3 375 mm Drill the holes Insert the dowels INFO Mount the Prevista Dry fixing set pursuant to the instruc tions for use for the fixing set Loosen the feet of the elem...

Страница 14: ...ccordance with the on site marking of the upper edge of the finished floor n X 1000 mm Tighten the feet of the element using a fork spanner The element is attached to the wall 9 Handling Prevista Dry...

Страница 15: ...8521 Mount the Prevista Dry Plus pre wall construction pur suant to the instructions for use of the Prevista Dry Plus system Position the element on the floor rail Fix the feet on the floor rail using...

Страница 16: ...Fix the element with the Prevista Dry Plus rail connectors The element is fixed in the Prevista Dry Plus pre wall construc tion Handling Prevista Dry washbasin element with concealed connection box 16...

Страница 17: ...together with the support profile Adjust the construction height of the element in accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Attach the element to the sup...

Страница 18: ...If applicable connect further elements to the element via the sup port profile Handling Prevista Dry washbasin element with concealed connection box 18...

Страница 19: ...the sanitary objects manufacturer Set the ledges to the desired height Turn in the threaded rods by hand Tighten the nuts of the threaded rods with a fork spanner Place the protective caps on the thre...

Страница 20: ...be cut out which for example can be used as a cable passage Cut out and remove the area with a cutting knife Lead the cable through the opening and secure Cut a suitable gypsum cardboard cladding pan...

Страница 21: ...basin fitting on one side using the copper pipe supplied If necessary cut the chrome plated pipe elbow supplied to the cor responding length Manufacture the second connection on the other side in the...

Страница 22: ...compression fitting Optionally connect the washbasin fitting to the concealed connec tion box using flexible hoses Align the corner valves When doing so align the pipe elbow to the marking aid line o...

Страница 23: ...chosen sanitary object Deburr the cut edge Grease the lip seal Insert the drain elbow through the cover plate in the lip seal of the odour trap Set the odour trap to the right size at the height The...

Страница 24: ...Requirement n The odour trap must be freely accessible Cut the water supply Disconnect the water line from the corner valve Turn the odour trap anti clockwise When doing so unlatch the clip to the rig...

Страница 25: ...g the corner valve counter the screw fitting with a spanner size 27 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance...

Страница 26: ...Viega Technology GmbH Co KG service technik viega de viega com INT 2020 07 VPN190462...