INSTALLATION
Limit Switches
3� Measure from the top platform to the top side brace tube�
Measure all 4 corners of the top platform�
All 4 corners must be identical� Use adjustment nuts on connector tubes as necessary�
4� Press and hold the ‘down’ button, and lower the top platform approx� 12” (approx� 30cm)�
4� Press and hold the ‘up’ button�
Once the platforms stops, the distance between the top platform and top side brace tube should be
identical to step 3�
Adjust the top limit switch as necessary to achieve the same measurement�
Connector
tube with
adjustment
nut�