background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

TECHNICAL MANUAL 
EDITION 2.0.0 

GSM DOOR INTERCOM 

SYSTEM 

(Vandal Resistant) 

Example panel only 

Содержание DIGITAL GSM DOOR INTERCOM SYSTEM

Страница 1: ...TECHNICAL MANUAL EDITION 2 0 0 GSM DOOR INTERCOM SYSTEM Vandal Resistant Example panel only...

Страница 2: ...PAGE 2 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0...

Страница 3: ...ing guide 14 Cable guide 15 Installation overview 15 Panel care 15 Testing power up and reset 16 Programming 17 26 Programming by text message 17 23 Programming by dial in 24 26 System operation 27 28...

Страница 4: ...nput Additionally a SPEAK BUSY and DOOR OPEN LED are available on the front of the module DDA facility to guide the caller through the call speak and door open stages of the call Programming of the te...

Страница 5: ...nto a telephone and using the telephones menu options to check it If a number is not programmed then it should be programmed while in the telephone The number can be obtained from the service provider...

Страница 6: ...l using modules from the VR4K range Either way it will include the Art 150 GSM module The GSM module pictured left includes all the GSM communication electronics SIM card Supplied seperately and conne...

Страница 7: ...a SMA male connector should be used An antenna is supplied along with an L mounting bracket Other types of GSM antenna can also be used Note An antenna must always be connected Note Always route the G...

Страница 8: ...L VER2 0 0 EXTENSION BUTTON MODULES The GSM intercom module will accept up to ten call buttons Any of the vandal resistant 4000 series button modules can be used as shown below VR4KBM 4 VR4KBM 5 VR4KB...

Страница 9: ...the code followed by clear Art 4800 Connections Connection Function 12 24V ac dc power input 0V power input C1 Common connection of relay 1 Dry contact NO1 Normally open connection of relay 1 Dry cont...

Страница 10: ...or relay 1 and then press enter This code will be used to open the door gate Relay 1 The code can be from 4 8 digits long and must be different from the engineer s code Enter a two digit relay 1 time...

Страница 11: ...eypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 Re Enter the engineer s code Alternati...

Страница 12: ...e code or gold finish Suffix G to the frame code Flush frames Surface frames POWER SUPPLY The GSM intercom panel is designed to work with power supplies of 12 14Vdc The power supply should be capable...

Страница 13: ...PAGE 13 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0 WIRING DIAGRAMS...

Страница 14: ...FOR PROGRAMMED TIME AUXILIARY OUTPUT OPEN COLLECTOR TRIGGERS WHEN C1 AI ARE SHORTED AUXILIARY INPUT TRIGGERS AUXILIARY OUTPUT AO AUXILIARY INPUT SENDS A SMS MESSAGE TO THE TELEPHONE NUMBER STORED IN M...

Страница 15: ...ing out any maintenance work on the system Avoid water ingress into the rear of the module always seal the module frame after installation using a suitable silicon based sealant All intercom and acces...

Страница 16: ...rd After approximately another 15 seconds another short beep will be heard The module is now fully initialised Note If you here a different combination of beeps in place of the last short single beep...

Страница 17: ...ailable codes DESCRIPTION CODE EXAMPLE SETTINGS DEFAULT PAGE Store a telephone no STN 1111STNnnn 01912243174 nnn 001 250 N A 19 20 Set call time SPT 1111SPTnn nn 01 12 02 40s 20 Set relay time RLT 111...

Страница 18: ...follows See important note on page 18 1111STNnnn yyyyyyyyyyy Store the telephone number yyyyyyyyyyy in position nnn 1111STNnnn yyyyyyyyyyy Store the telephone number yyyyyyyyyyy in position nnn and se...

Страница 19: ...be sent to the sender with the stored number for that location 1111STNnnn Delete the telephone number stored in location nnn where nnn 100 250 1111STNnnn Delete and confirm deletion of a telephone nu...

Страница 20: ...Query the current stored time A text message will be sent to the sender showing the stored time SET AO AUXILIARY OUTPUT TIME FOR AOM 01 ONLY The AO time can be from 01 99 seconds or latching Set the A...

Страница 21: ...the connection This time period is reset after each call made on the system and will only happen if the full time period elapses without any incoming or outgoing calls 1111NODnn Store the time nn time...

Страница 22: ...used when setting up the SIM card For example disabling the voicemail facility or disabling automatic SMS messages or missed calls Any number up to 15 digits can be called and the call will last for...

Страница 23: ...ent to the OEM GSM module 1111PRG command Send an AT command to the OEM module STORE CREDIT BALANCE CHECK STRING Several network providers offer the facility to check available balance on their pay as...

Страница 24: ...y in programming mode until the call ends or a timeout occurs The timeout will occur after 30 seconds if no buttons are pressed This is reset to 30 seconds each time a button is pressed Note At any po...

Страница 25: ...utton 10 C2 e 10 20 Use the chart on page 26 to record the telephone numbers stored SET CALL TIME The call time is the maximum time in seconds that a call can last before the intercom panel automatica...

Страница 26: ...e count down begins from when the call button is pressed and can be set to 01 99 seconds 56nn Store the time nn time in seconds DIVERT SETUP Divert can be set for any or all of the call buttons When s...

Страница 27: ...ectly for this feature Simply dial the number of the intercom panel The intercom panel will drop the call and then open the gate door for the programmed time USER COMMANDS The following commands can b...

Страница 28: ...bly missing DTMF tones and network loss A signal strength of 99 indicates it could not be detected DIALLING INTO THE INTERCOM FROM ANOTHER TELEPHONE There are three possible outcomes to dialling into...

Страница 29: ...6 Button 6 Divert 016 Button 7 007 Button 7 Divert 017 Button 8 008 Button 8 Divert 018 Button 9 009 Button 9 Divert 019 Button 10 010 Button 10 Divert 020 DIAL IN ACCESS CONTROL MEMORY RECORD SHEET M...

Страница 30: ...134 210 135 211 136 212 137 213 138 214 139 215 140 216 141 217 142 218 143 219 144 220 145 221 146 222 147 223 148 224 149 225 150 226 151 227 152 228 153 229 154 230 155 231 156 232 157 233 158 234...

Страница 31: ...the text message is incorrect If you are unsure of the 4 digit code try resetting it to 1111 Long beep followed by short beep while the system is in use Manually ending a call by pressing a call butto...

Страница 32: ...provider if you are not sure Check the number you are sending the message to is correct The number of the SIM card in the intercom panel After sending a SM to the intercom panel Listen for a single s...

Страница 33: ...provided the Enfora Enabler IIG module meets maximum permissible exposure MPE limits for general population uncontrolled exposure at defined in section 1 1310 of the FCC Rules and Regulations WARNING...

Страница 34: ...36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0 Date Software Version Revision 07 04 2009 GSMVR0 0 1 Initial release 10 12 2010 GSMVR1 0 0 New hardware release Additional reset software added Busy...

Страница 35: ...PAGE 35 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0...

Страница 36: ...ity Ltd Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT...

Отзывы: