PAGE 9 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL
VER2.0.0
CODELOCK MODULE (VR4KCLM, 800CL)
The codelock includes three relay outputs (Only 2 on the 800CL), two push to exit button
inputs and operates from a 12-24V ac/dc power supply. Up to 2 unique codes can be
programmed, each in the range of 4-8 digits. Relay time can be programmed from 01 – 99
seconds or set to latching mode with a relay time of 00 (To latch, type in the code followed
by Enter, to unlatch, type in the code followed by clear).
Art.4800 Connections
Connection Function
+
12-24V ac/dc power input
-
0V power input
C1
Common connection of relay 1 (Dry contact)
NO1
Normally open connection of relay 1 (Dry contact)
NC1
Normally closed connection of relay 1 (Dry contact)
C2
Common connection of relay 2 (Dry contact)
NO2
Normally open connection of relay 2 (Dry contact)
NC2
Normally closed connection of relay 2 (Dry contact)
C3
Common connection of relay 3 (Dry contact)
NO3
Normally open connection of relay 3 (Dry contact)
NC3
Normally closed connection of relay 3 (Dry contact)
SW1
Push to exit input for relay 1 (Triggered by 0V)
SW2
Push to exit input for relay 2 (Triggered by 0V)
Содержание DIGITAL GSM DOOR INTERCOM SYSTEM
Страница 1: ...TECHNICAL MANUAL EDITION 2 0 0 GSM DOOR INTERCOM SYSTEM Vandal Resistant Example panel only...
Страница 2: ...PAGE 2 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0...
Страница 13: ...PAGE 13 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0 WIRING DIAGRAMS...
Страница 35: ...PAGE 35 of 36 VR GSM DOOR INTERCOM TECHNICAL MANUAL VER2 0 0...