66250457-EN - V 3.4 - 31/08/16
5
VK4K/6256 Series “6 wire Bus” videokit
VK4K/6256 Series - Installation handbook
General directions for installation
CONNECTION TO MAINS
The system must be installed according to national rules in force, in particular we recommend to:
• Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in each
pole and shall disconnect all poles simultaneously;
• The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
• Remove the terminal side covers by unscrewing the retaining screws;
• Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
• Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams;
• Check the connections and secure the wires into the terminals;
• Replace the terminal covers and fix them using the relevant screws;
• When all connections are made, restore the mains.
CABLE SIZE
Video connections and Audio connections must be wired in twisted pair: pair the video lines (terminals/signals “V1” and “V2”),
pair the audio lines (terminals /signals “1” and “2”).
+V *
– *
1
V1
V2
2
Power
supply
Videophone
Up to 40mt
2 wires
Ø 1mm2
20mt max
Outdoor
station
BROWN
ORANGE
BLUE
GREEN
WHITE/BROWN
WHITE/ORANGE
WHITE/BLUE
WHITE/GREEN
Distance Suggested cables type
Up to
40mt
CAT5/CAT6 FTP/UTP
AWG24
* Couple the two wires to
double the section.
1
V1
V2
+V
–
2
1
V1
V2
+V
–
2
1
V1
V2
+V
–
2
Power
supply
Videophone
Up to 50mt
Outdoor
station
Outdoor
station
Outdoor
station
"+V" and "–"
Ø 0.35mm2
"V1" and "V2"
Ø 0.35mm2 Twisted pair
"1" and "2"
Ø 0.35mm2 Twisted pair
20mt max
2 wires
Ø 1mm2
from 50 to 100mt
"+V" and "–"
Ø 0.75mm2
"1" and "2"
Ø 0.5mm2 Twisted pair
"V1" and "V2"
Ø 0.5mm2 Twisted pair
from 100 to 200mt
"+V" and "–"
Ø 1.5mm2
"V1" and "V2"
Ø 0.75mm2 Twisted pair
"1" and "2"
Ø 0.75mm2 Twisted pair
Distance Suggested cables type
Up to
50mt
Belden 9746 or equivalnet
4 pair (8 cores) 0.35mm2
AWG22 - 48Ω/Km
From
50 to
100mt
Belden 9690 or equivalnet
3 pair (6 cores) 0.8mm2
AWG18 - 19.2Ω/Km
From
100 to
200mt
Belden 9157 or equivalnet
4 pair (8 cores) 0.8mm2
AWG18 - 19.2Ω/Km