VK4K/6256 Series “6 wire Bus” videokit

VK4K/6256 Series - Installation handbook

BUZZER BACK EMF
When using intercoms with buzzer call (Art.924/926, SMART1/2, 3101/2, 3001/2 and 3021/2) add one 0.1uF (100nF) capacitor be-

tween terminals 3 and 6 on the telephone.

BUILT-IN RELAYS – BACK EMF PROTECTION
The Art. 4800M includes selectable back EMF protection on the relays. The jumpers marked MOV (One jumper for each relay) are 

used to select the protection type. When using a fail secure lock with connections C & NO the jumper should be in the NO position. 

When using a fail open lock with connections C & NC the jumper should be in the NC position and when using the codelock to 

trigger a gate controller or another third party controller the jumper should be removed completely (This disables the protection 

on the relay).

PROGRAMMING (SEE ALSO THE RELEVANT FLOW CHART)
•  Enter the “ENGINEER’S CODE”: first time type six times “1” (111111 factory preset) and press “ENTER” (The red LED will illuminate);

•  Confirm “ENGINEER’S CODE” (typing again the same) or type the new code (4 to 8 digits) then press “ENTER” (Melody). Pressing 

twice the “ENTER” button without changing the “ENGINEER’S CODE”, will exit from the programming;

•  Enter the code (4 to 8 digits) to enable “RELAY 1” or re-enter the existing code then press “ENTER” (Melody);

•  Enter the “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then 

press “ENTER” (Melody);

•  Enter the code (4 to 8 digits) to enable “RELAY 2” or re-enter the existing code then press “ENTER” (Melody);

•  Enter the “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then 

press “ENTER” (Melody);

•  Enter the code (4 to 8 digits) to enable “RELAY 3” or re-enter the existing code then press “ENTER” (Melody);

•  Enter the “RELAY 3” operation time (2 digits 01 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then 

press “ENTER” (Melody);

•  The system is ready to use (the red LED will be off).

PROGRAMMING NOTES
•  After pressing enter following a command, press “ENTER” a further twice to exit the programming menu.

RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
•  Turn off power to code lock;

•  Keep “ENTER” button pressed while turning the power back on;

•  Release “ENTER” button;

•  The engineer’s code is now set to “111111” (six times one).

OPERATION
•  Type in the programmed code and press “ENTER”;

•  If the code is correct, the green LED will illuminate for ap-

prox. 2 seconds and the relay relevant to the code will oper-

ate for the programmed time;

•  If a wrong code is entered, a continuous melody will sound 

for 4 or more seconds, according to the number of mistakes;

•  To switch off any relay while operating, type in the relevant 

code then press the “CLEAR” button;

OPERATION NOTES
•  To operate relays together, set the same code for each relay;

•  If a wrong code is entered, the system will lock out for 5 sec-

onds which will increase each time a wrong code is entered. 

The system will operate only when the correct code is entered. 

TERMINALS:
SW2

Relay 2 command signal (active low)

SW1

Relay 1 command signal (active low)

NC3

Relay 3 normally closed contact 

Max

24Vac/dc

3A

NO3

Relay 3 normally open contact 

C3

Relay 3 common contact

NC2

Relay 2 normally closed contact 

NO2

Relay 2 normally open contact 

C2

Relay 2 common contact

NC1

Relay 1 normally closed contact 

NO1

Relay 1 normally open contact 

C1

Relay 1 common contact

12/24Vac/dc power input

+

Art. 4800M 

 Digital codelock module

Содержание 6256

Страница 1: ...31 08 16 VIDEOKIT VK4K 6256 SERIES 6 Wire bus one way two way videokit Installation handbook VK4K VK4KC 6256 We recommend This equipment is installed by a Competent Electrician Security or Communications Engineer English ...

Страница 2: ...ry contact relay 2 capacitor discharge 12Vdc output Facility for the connection of a codelock Art 4800M display module Art 4820 stand alone proximity reader Art 4850 or stand alone biometric reader Art 4821 etc Programmable number of call tone rings from 2 to a maximum of 8 Input for local door bell push button Programmable timed privacy function from 15 minutes to a maximum of 8 hours Door open s...

Страница 3: ...oor station composed of 1Art 4833 1 C 1buttoncameraunit 1Art 4851 Flushmountingbox 1 Colour videophone Art 6256 1 Power supply Art 850K VK4K 1S 6256 surface mounting 1 Outdoor station composed of 1Art 4833 1 C 1buttoncameraunit 1Art 4881 Surfacemountingbox 1 Colour videophone Art 6256 1 Power supply Art 850K TWO WAY VERSIONS VK4K 2 6256 flush mounting 1 Outdoor station composed of 1Art 4833 2 C 2b...

Страница 4: ...odule 1Art 4852 Flushmountingbox 1 Colour videophone Art 6256 1 Power supply Art 850K VK4KC 1S 6256 surface mounting 1 Outdoor station composed of 1Art 4833 1 C 1buttoncameraunit 1Art 4800M Codelockmodule 1Art 4882 Surfacemountingbox 1 Colour videophone Art 6256 1 Power supply Art 850K TWO WAY VERSIONS VK4KC 2 6256 flush mounting 1 Outdoor station composed of 1Art 4833 2 C 2buttonscameraunit 1Art ...

Страница 5: ...screws When all connections are made restore the mains CABLE SIZE Video connections and Audio connections must be wired in twisted pair pair the video lines terminals signals V1 and V2 pair the audio lines terminals signals 1 and 2 V 1 V1 V2 2 Power supply Videophone Up to 40mt 2 wires Ø 1mm2 20mt max Outdoor station BROWN ORANGE BLUE GREEN WHITE BROWN WHITE ORANGE WHITE BLUE WHITE GREEN Distance ...

Страница 6: ...ing the conversation it is not possible to open the door but the key LED on the door station switches on for the program med time Incorrect position of J2 jumper Electriclockwiresunconnectedorinshort Wrong electric lock type Check J2 position on the door station Check connection Check that the electric lock type ac or dc is suitable for the J2 position chosen Speech only from outside to inside Wir...

Страница 7: ...h multiple entrances The LED will be off when the system is in stand by If illuminated indicates that the call from the outdoor station is in progress The LED will switch OFF when the call is answered or after the programmed number of rings If illuminated indicates that it is possible to speak because the call has been answered The LED will switch OFF at the end of a conversation or at the end of ...

Страница 8: ... button calls a different videophone L Both buttons call the same videophone Address 1 H L J1 J2 J3 J4 J4 Position Built in relays back EMF protection MOV H NC contact L NO contact When the door open relay operating mode is set to capacitor discharge one terminal of the electric lock must be connected to ground while the second must be connected to NO terminal The NO terminal will supply a tempora...

Страница 9: ...nnect the components to the lock releases as shown in figures VARISTOR MOV 12V AC LOCK RELEASE Fig 1A DIODE 1N4002 12V DC LOCK RELEASE Fig 1B SIGNALS V Power input 16 20Vdc Power input ground 12Vout 12Vdc 0 3A max output to supply accessiories 1 Speech line input toward the loudspeaker and data signal about 12V in stand by about 5V with a conversation in progress 2 Speech line output from the micr...

Страница 10: ...ustic signal during operating and programming Keypad illumination LEDs GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment strictly keeping to the items indicated on each schematic and follow these General Directions for Installation The system must be installed according to national rules i...

Страница 11: ...0 remain open time or re enter the existing time then press ENTER Melody Enter the code 4 to 8 digits to enable RELAY 3 or re enter the existing code then press ENTER Melody Enter the RELAY 3 operation time 2 digits 01 to 99 I E 05 5 seconds 00 remain open time or re enter the existing time then press ENTER Melody The system is ready to use the red LED will be off PROGRAMMING NOTES After pressing ...

Страница 12: ...PRESS ENTER ENTER ACCESS 2 TIME AND PRESS ENTER ENTER ACCESS 3 CODE AND PRESS ENTER ENTER ACCESS 3 TIME AND PRESS ENTER SYSTEM READY TO USE First time 6 times 1 111111 factory preset Type again six times 1 or the new enginner s code 4 to 8 digits Code to enable relay 1 4 to 8 digits Code to enable relay 2 4 to 8 digits 2 digits 01 to 99 I E 05 5 seconds 00 remain open time 2 digits 01 to 99 I E 05...

Страница 13: ...ndbook 4000 Series Surface and flush mounting door station installation H G H Y G C F E D B A C L H L P O N M H M M C Q P C D W N N C H fig 1 fig 8 fig 4 fig 5 fig 6 fig 7 fig 3 fig 10 fig 11 fig 15 fig 12 fig 16 fig 13 fig 17 fig 14 fig 18 fig 2 fig 9 EXAMPLE INSTALLING A FOUR MODULE OUTDOOR STATION ...

Страница 14: ...m has been tested and is working correctly move back the module support frames carefully fix them to the surface box using the screwdriver provided P torx end and the pin machine torx screws Q Fig 11 Note do not over tighten the screws more than is necessary INSTALLING A FLUSH MOUNTING DOOR STATION When flush mounting and the number of modules is greater than 3 the required back boxes need to be l...

Страница 15: ...he speech is also live and the door can be opened by pressing Door open intercommunicating call button With the handset lifted and speech lines open to the entrance panel press this button to open the door If the termi nal LD is properly connected the relevant LED remains switched ON until the door is closed Intercommunication only works when the system is in stand by condition Switch 4 of the SW1...

Страница 16: ...Apartment Address OFF 1 ON 2 Switches 2 3 Extension Address OFF OFF 1 ON OFF 2 OFF ON 3 ON ON 4 Switch 4 Intercommunication OFF Between videophones of the two apartment ON Between videophones in the same apartment Switches 5 6 Number of rings OFF OFF 2 ON OFF 4 OFF ON 6 ON ON 8 Switches 7 8 Privacy duration time OFF OFF 15 minutes ON OFF 1 hours OFF ON 4 hours ON ON 8 hours 2 WAY DIP SWITCH SW2 Th...

Страница 17: ...o signal 1 sync V2 Balanced video signal 2 sync 24Vac 1A max power input LB Local call input 5V in standby 0V to trigger SB Service button open collector active low output The button goes active when the button is pressed Open Collec tor 24Vdc 100mA max LD 12Vdc input for door open LED 2A Speech line input toward the loudspeaker of the parallel telephone Approx 12V in stand by 3V during a conversa...

Страница 18: ...3 make the holes A insert the wall plugs B and fix the base with the screws C feeding the wires D into the hole E If you have used the box 503 fix the base to the wall through the holes F using the screws C 4 As shown in Fig 4A connect the wires to the removable terminals following the provided installation diagram Connect the ter minal blocks to the electronics contained in the cover as shown in ...

Страница 19: ...vant connection board then after a few seconds reconnected again to allow the recognizing of the new setting All diagrams shown are valid for B W or colour systems with surface or flush mount door station DECLETION OF RESPONSIBILITY This manual has been written and revised carefully The instructions and the descriptions which are included in it are referred to VIDEX parts and are correct at the ti...

Страница 20: ...tofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains and reconnect Videx Electronics S p A Via del Lavoro 1 63020 Monte Giberto AP Phone 39 0734 631669 Fax 3...

Страница 21: ... Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains and reconnect Local Bell Local ...

Страница 22: ...2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 Art 4800 Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to...

Страница 23: ...finche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains and reconnect Local Bell Local Bel...

Страница 24: ... BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In ord...

Страница 25: ... C01 NC2 NO1 CO2 NO2 NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 2 Art 4833 1 NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 4 3 2 1 ON 1 Art 4833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Local Bell Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togli...

Страница 26: ... 1 1 Marco Rongoni vk4k62h 010 dwg 17 11 2015 17 11 2015 1 Art 4833 1 Art 4900 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max 1 Art 4833 1D Push to Exit Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make ...

Страница 27: ... 4833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system recognize any modification...

Страница 28: ...arco Rongoni vk4k62h 012 dwg 17 11 2015 18 11 2015 1 Art 4833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max 1 Art 4833 1D Push to Exit 1 Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system re...

Страница 29: ...xit 1 2 Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema è necessario togliere l alimentazione di rete all impianto e restituirla In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains and reconnect Local Bell...

Страница 30: ...ut V C NO 4 3 2 1 ON 1 Art 4833 1 Art 506N 1 4 2 3 5 NC1 C01 NC2 NO1 CO2 NO2 Push to exit Push to exit 20V GND 1 2 V1 V2 18Vdc 230V ART 323 18 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669 www videx it info videx it Autore Data modifica Data creazione Title Notes Titolo Note Cod File Foglio 1 1 Marco Rongoni vk4k 1 001 2e dwg 29 10 2015 29 ...

Страница 31: ... 1 ON 1 Art 4833 1 4 3 2 1 ON 2 Art 4833 1 Art 506N 1 4 2 3 5 NC1 C01 NC2 NO1 CO2 NO2 4 3 2 1 ON 3 Art 4833 1 Art 506N 1 4 2 3 5 NC1 C01 NC2 NO1 CO2 NO2 4 3 2 1 ON 4 Art 4833 1 Art 506N 1 4 2 3 5 NC1 C01 NC2 NO1 CO2 NO2 1 2 3 4 5 6 7 8 1 2 ON Address N ON V _ 1 2 V1 SB LD 2A 3A 4A SW2 SW1 LB V2 5A 1 Ext 1 Art 6256 18Vdc 230V ART 323 18 18Vdc 230V ART 323 18 18Vdc 230V ART 323 18 Installation diagr...

Страница 32: ...sprey Trinity Park Trinity Way LONDON E4 8TD Phone 44 0870 300 1240 Fax 44 020 8523 5825 www videx security com marketing videx security com Northern UK office VIDEX SECURITY LTD Unit 4 7 Chillingham Industrial Estate Chapman Street NEWCASTLE UPON TYNE NE6 2XX Tech Line 44 0191 224 3174 Phone 44 0870 300 1240 Fax 44 0191 224 1559 Greece office VIDEX HELLAS Electronics 48 Filolaou Str 11633 ATHENS ...

Отзывы: