3.7 Golden rules
1
Area 1 is always
delayed.
When you register a keypad or a badge
reader into an area, that area will automatically be delayed.
2
Never position
a panel next to
a high voltage electrical cabinet
.
3
Press CLR to erase a typing mistake.
4
Never register the same device twice (delete from the system first).
5
Registration of
up to 25 devices
(including the keypad).
6
Respect indoor infrared devices installation height (
2m10 to 2m30)
.
7
Outdoor cameras have to be installed at
2m60 to 3 meters
height
. Those devices needs to to protect an access and not a zone.
8
Do not fix the keypad at the beginning of the installation as it will
need to be portable during programming.
Always clean
the lens of the cameras after the installation
(Use a clean, dry cloth, taking care not to exert pressure on
the
lens).
9
10
To switch between UPPER and lower case, use the M/m
key from the CMA keypad or hold a digit key (0 to 9) for
XMA/XMB.
11
Internal components are fragile, be careful opening or
closing the panel.
LCD screen goes dark after 30 seconds of inactivity, press an
arrow or numeric key to light it up.
13
Use only batteries provided by Videofied (siren : Alkaline
batteries).
14
Infrared detectors should never be installed in stairs or close
to stairs (false alarm risks).
15
A colon display [:] means that the parameter can be
changed.
12
18
INSTALLATION MANUAL
3. XTO-IP FEATURES GUIDE
XTO-IP
Alarm panel
When user disarms the system, the
keypad indicates the last event.
In case of the user needs to read the full
log file, use the keypad to go in EVENT
LOG, press
OK or YES
on SELECT LAST
EVENTS and use arrow to list the events.
3.6 Read the event log
Press
OK or YES
for more information about an event
EVENT
LOG
SELECT LAST
EVENTS
OK
or
YES
15/10/13
11:29
MODIFIED PARAMET
OK
or
YES
15/10/13
11:10
SYSTEM DISARMED