background image

I N S T A L L A T I O N   S H E E T

2

BR250/651/752 Badge Reader

www.videofied.com

During arming

The arming stops. 

The two indicators flash 

green for  5s then turn off: A 

fault was detected. 

In order to know more 

about what happened a 

keypad is required.

Without action from the 

user, arming will start 

again after 3 min and the 

concerned detector will be 

bypassed from this arming.

Flashing of the top red 

indicator (only) every 

second during arming 

delay. 

The top red indicator 

flashes every two 

seconds indicating that 

the system is armed.

Everything is fine : 

System is arming

Problem was 
identified during 
the incomplete 
arming (detection 
in and instant area)

The LEDs will stay 

on for 5 seconds

The two indicators turn off, the system is 

disarmed.

There was no alarm

An alarm 

triggered on

The top indicator 
flashes green for 
2s, and that of the 
bottom flashes 
fixed green light 
and the reader 
beeps 4 times

The two indicators 

remain on with 

fixed green light 

for 5 seconds

When reading the badge, the reader emits a beep, then two 

beeps indicating the badge has been accepted. The LED 

indicators of the reader are going to indicate a message:

When reading the badge, the reader emits a beep, then two 

beeps indicating the badge has been accepted. The LED 

indicators of the reader are going to indicate a message:

Functioning of indicators

During disarming

Verify with a keypad 

in order to know more 

about what happened

Содержание BR250

Страница 1: ...g 1 Mount the base to the wall observing the TOP marking 2 Insert 3 6V DC LS14500 Lithium batteries observing correct polarity 3 With the programming keypad browse to the ADD A NEW DEVICE menu Level 4 4 Press OK YES The keypad displays PRESS PROGRAM BUTTON OF DEVICE 5 Press program button The button blinks in green Wait for keypad to display BADGE READER n RECORDED 6 Press OK YES The display shows...

Страница 2: ...he incomplete arming detection in and instant area The LEDs will stay on for 5 seconds The two indicators turn off the system is disarmed There was no alarm An alarm triggered on The top indicator flashes green for 2s and that of the bottom flashes fixed green light and the reader beeps 4 times The two indicators remain on with fixed green light for 5 seconds When reading the badge the reader emit...

Страница 3: ...ommunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase ...

Страница 4: ...amper Display lighting Automatic 2 LED Built in sounder Emits arm and disarm beeps Operating temperature 25 70 C 13 158 F Maximum relative humidity 95 non condensing Physical Data Protection rating IP44 IK08 Material Polycarbonate UL94 Dimensions 140 mm x 90 mm x 38 mm LxWxD 5 1 2 in x 3 1 2 in x 1 1 2 in Weight 136 g 4 8oz without batteries Installation Mounting Unit Base 2 screws secure the Badg...

Отзывы: