20
5.5.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to ‘off’, except for DS-2).
DS-1 Panel option
off
DS-2 Panel option
on
DS-3 Ch. voltage
off
DS-4 Ch. voltage
off
DS-5 Frequency
off
DS-6 Search mode
off
DS-7 AC-in Limit
off
DS-8 Store setting
→ ←
DS-1
off
DS-2
on
DS-3
off
DS-4
on
DS-5
off
DS-6
off
DS-7
on
DS-8
→ ←
DS-1
on
DS-2
off
DS-3
on
DS-4
on
DS-5
on
DS-6
on
DS-7
off
DS-8
→ ←
Example 1: (factory setting)
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
GEL 14.4V
5
Frequency: 50Hz
6
Search mode off
7
AC-in Limit 12Amp
8 S
tore setting: off→ on→ off
Example 2
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
AGM 14,7V
5
Frequency: 50Hz
6
Search mode off
7
AC-in Limit 4Amp
8 S
tore setting: off→ on→ off
Example 3
1
Panel or remote
switch connected
2
Panel or remote
switch connected
3, 4
Tubular plate 15V
5
Frequency: 60Hz
6
Search mode on
7
AC-in Limit 12Amp
8 S
tore setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from ‘off’ to ‘on’, and then back to ‘off’.
The LEDs ‘charger’ and ‘alarm’ will flash to indicate acceptance of the settings.
Содержание EasySolar 12 1600
Страница 2: ......
Страница 32: ...30 ...
Страница 62: ......
Страница 92: ......
Страница 122: ......
Страница 153: ...31 EN NL FR DE ES Appendix ...
Страница 154: ......
Страница 155: ...EN NL FR DE ES Appendix www victronenergy com Appendix A overview connections ...
Страница 156: ...Appendix B installation information ...
Страница 157: ...EN NL FR DE ES Appendix www victronenergy com Appendix C Inverter PCB connections ...
Страница 158: ...Appendix D DIP switches ...
Страница 159: ......