03.2021
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA 8
13
10.2.4. Installer settings.
Types of settings for Installer (entered with installer password)
Factory settings
Duration
600 sec. (300
÷
990)
Initial filling
90 sec. (10
÷
99)
Fan
1500 rpm
Screw feeding
2,5 sec. (0,1
÷
15)
Screw Cycle
30 sec. (1
÷
100)
Temperature/ON
60
0
C
Temperature/OFF
90
0
C
Repetitions
2
Second filling
30 sec. (10
÷
250)
Duration
180 sec. (100
÷
600)
Fan
1600 rpm
Screw feeding
3 sec. (0,1
÷
15)
Screw Cycle
15 sec. (1
÷
100)
Temperature
difference/deg.
0 1 2 3 4
Fan / rpm
1100 1200 1300 1400 1500
Second Fan/%
50 60 70 80 90
Screw feeding/sec.
1,2 1,6 1,5 1,5 1,5
Screw cycle/sec.
7 7 6 5 4
In this menu a selection can do among four display
languages: Bulgarian, English, Dutch, and German.
10.2.5. Service technician settings.
Types of settings for service technician (entered with
service technician password)
Parameter
Factory settings
Switch-on Temperature
Here one can set the Smoke gases, which the
air fan on at.
110
0
C
Hysteresis
This is the thermal lag at which the room fan
will stop operating. I.e. if it has been set to
switch on at 110
°С
, it will stop at 90
°С
, if the
hysteresis is 20
°С.
It can be set within the range of 1
°С
to 50
°С.
20
0
C
Initial Purge
In Initial Purge the duration of the operation of
the smoke fan can be set to 100% in seconds in
the
Start Mode
.
60 sec. (30
÷
250)
Extinct Fire
In extinct fire one can set the duration for the
smoke fan to operate at 100 % in Clean Mode.
This mode gets active if the control unit
transfers to switch-off and extinction of the
fireplace!
300 sec.
(100
÷
2000)
Содержание VITTORIA 8
Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...
Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Страница 20: ...Victoria 05 Ltd 20...
Страница 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...
Страница 22: ...Victoria 05 Ltd 22...