background image

Victoria-05 Ltd.

 

 

 

18 

 

 

14.Check list. 

Location and installation: 

-

 

Ventilation of the room; 

-

 

Only the flue outlet of the pellet stove is connected to the chimney; 

-

 

Connecting flues pipes have a horizontal section with a length of 2 m, minimum  slope of 3%, not more  than two 

curves at 90° and a vertical section with a length of less than 1.5 m

-

 

Connecting flues pipes are made of suitable material. It is recommended stainless steel; 

Operation: 

-

 

Well dried and of good quality wood pellets. Diameter 

of Ø 6 mm and maximum 

moisture content of 8%; 

-

 

Chimney, connecting flue pipes and combustion chamber are clean; 

-

 

Flue outlet pipes are clean. 

 

15.Frequently Asked Questions. 

The following answers are tentative. For more details, use the instruction manual. 

-

 

What is need to prepare and do before installing the pellet stove? 

Chimney with a diameter of at least 80 mm. 

Opening for fresh air with a cross section not less than 80 cm

2

Power supply 230V (+/- 10%), 50Hz. 

-

 

Can the flue gasses be sent out directly through the wall? 

NO.  Removal  must  be  in  accordance  with  existing  standards.  For  proper  operation  of  the  pellet  stove  the  chimney 

(metal or masonry has to be completed by one of the proposed variants at Fig. 3.1. It must provide protection from wind. 

-

 

Is it required to ensure fresh air supply in the room? 

-

 

Yes,  external  air  supply  ensures  fresh  air  for  the  burning process.  Fume  extractor  pulls  air  from  the  room  to  the 
combustion chamber. 

-

 

What settings does the control panel of pellet stove need? 

Setting for the desired room temperature. Pellet stove will regulate the power to that temperature. The installer must 

make the appropriate setting. 

-

 

How often the combustion chamber should be cleaned? 

Before each ignition of the pellet stove, but only when it is turned off and cold. 

-

 

May you clean the pellet fuel hopper with a vacuum cleaner? 

Yes, at least once a month or if the pellet stove has not worked for a long time. 

-

 

Can you use other types of fuel than wood pellets? 

NO. Pellet stove is designed to work with wood pellets with a diameter of 

Ø 6 mm. The use of another type of fuel leads 

to damage. 

 
 

 

Содержание VITTORIA 8

Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...

Страница 2: ...ONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 13 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 OUTS TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUELLIN...

Страница 3: ...ailure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the fo...

Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Страница 5: ...Alarm Exhaust gases Pressostat Connected to the combustion chamber It reads the values of the vacuum in the combustion chamber and compares it with the pressure in the room Temperature sensor of the...

Страница 6: ...m Pressure Switch Pressostat Measures the vacuum in the combustion chamber 7 Operating mode Pellet stove works with wood pellets They are cylindrical granules made of pressed wood whose combustion is...

Страница 7: ...rea Pellet stove is designed developed programmed and tested to operate with wood pellets class A1 according to EN plus and BDS EN ISO 17225 2 2014 with the following parameters Maximum diameter 6 mm...

Страница 8: ...to ensure a sufficient supply of oxygen necessary for combustion Additionally it can be delivered outside air through a pipeline of 50 mm In this case it is possible to emerge condensate If necessary...

Страница 9: ...llet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be cleaned with a soft brush or a dry cloth but in any case not with a d...

Страница 10: ...utton a green bar appears at the bottom of the display Wait until it is full to execute the command Hiding the green bar means that the value is stored correctly The return icon is removed during the...

Страница 11: ...le is connected 0 no module 1 a module is present but is not connected 2 a module is connected to the router Languages Here there is a Control Unit Language shortcut key The system offers four languag...

Страница 12: ...e fireplace will stop The settings have been restricted in four access levels The first level is Installer The second level is Service Technician The third level is Delete Errors with a password 7777...

Страница 13: ...ion can do among four display languages Bulgarian English Dutch and German 10 2 5 Service technician settings Types of settings for service technician entered with service technician password Paramete...

Страница 14: ...pellets loading The capacity of the pellet fuel hopper is 24 kg The opening for charging the hopper is with dimensions 167 300 mm If the hopper is left without pellets the pellet stove will stop worki...

Страница 15: ...in the end P1 Switching among these is based on the temperature pre set as room temperature If the room temperature is set to 30 in the Modulation 5 Menu the Thermal Difference one should set is 4 in...

Страница 16: ...ve was not used for an extended period Clean the ignition 12 3 Seasonal maintenance performed by the installer The user has to contact the installer to perform the seasonal maintenance Disconnect the...

Страница 17: ...cted alarm s activation on the right To delete the alarms on the right enter the password 7777 To delete the alarms on the left too enter the password again Pressure Switch Activated if insufficient v...

Страница 18: ...an the flue gasses be sent out directly through the wall NO Removal must be in accordance with existing standards For proper operation of the pellet stove the chimney metal or masonry has to be comple...

Страница 19: ...r 4 Ignition 18 Left side plate 5 Pressure switch 19 Right side plate 6 Controller set 20 Special tool 7 Display 21 Fume temperature sensor 8 Crossflow blower 22 Thermostat of the pellet fuel hopper 7...

Страница 20: ...Victoria 05 Ltd 20...

Страница 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...

Страница 22: ...Victoria 05 Ltd 22...

Страница 23: ...maining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following...

Страница 24: ...for repairs under warranty Company Receipt date Type of repair Delivery date Carried out Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 e mail in...

Отзывы: