3. Only if the meter is used with the matched 

meter  pen,  can  it  meet  the  requirement  of 

safety standard. When the line of the meter 

pen  is  damaged,  it  is  necessary  to  replace 

another one of the same model or the same 

electrical specification. 

4. 

Don’t  use  other  unconfirmed  or 

disapproved  protector  tube  to  replace  the 

protector  tube  inside  the  meter.  Only  the 

protector  tube  of  the  same  model  or  same 

specification  can  be  replaced.  Before  the 

replacement,  the  test  leads  must  leave  the 

measuring point and ensure there is no any 

signal at the input terminal. 

5. 

Don’t  use  other  unconfirmed  or 

disapproved  battery  to  replace  the  battery 

inside  the  meter.  Only  the  battery  of  the 

same 

model 

or 

same 

electrical 

specification  can  be  replaced.  Before  the 

Содержание VR-81D

Страница 1: ...rmance and high reliability It could be used to measure DC voltage AC voltage DC current AC current resistance temperature capacity frequency duty cycle diode and make on and off test Meanwhile it is...

Страница 2: ...al tool in laboratory and factory as well as for radio fans and family Open package Inspection Open the package box and take out the meter check carefully if the following accessories are absent or da...

Страница 3: ...e first read the safety considerations 1 When DC voltage above 30V AC voltage above 25V current above 10mA AC power line with inductive load or power line during electric fluctuation is measured pleas...

Страница 4: ...other unconfirmed or disapproved protector tube to replace the protector tube inside the meter Only the protector tube of the same model or same specification can be replaced Before the replacement t...

Страница 5: ...d don t touch uncovered metal terminal output port lead clamp and etc where earth potential may exist Dry clothes rubber shoes rubber cushion and other insulating material are usually used to keep you...

Страница 6: ...order to avoid electric shock and the damage to the meter 9 When the test leads is inserted into the current socket don t measure any voltage for fear that the meter should be damaged and the operato...

Страница 7: ...to switch the function range selection switch during measurement 12 When is shown on LCD display please replace battery immediately to ensure the measurement precision 13 It is not allowed to insert t...

Страница 8: ...t Panel Button Function Description 1 Instrument Model Number 2 LCD Display Display the measured data and unit 3 Function Button 3 1 SELECT function switch Press this button the function could switch...

Страница 9: ...the reading is locked Press it again the lock is cleared and enter into normal measurement status 3 4 REL Relative Value Measurement The relative value measurement of all functions could be conducted...

Страница 10: ...rature and Input terminal with current less than 400mA V Other Functions Automatic Power off During measurement the meter will automatically shut down enter sleeping mode to save power if function but...

Страница 11: ...roperty 1 1 Display LCD 1 2 Max Display 3999 3 3 4 counts automatic polarity display and unit display 1 3 Measuring Method Dual integral A D converter 1 4 Sampling Rage Approx 3 times sec 1 5 Over Ran...

Страница 12: ...1 5V batteries 1 12 Accessories Instruction Manual 1 pc Holster 1 pc Outer packing box 1 pc 10A test leads 1 pair K Thermocouple and 1 5V batteries 2 pcs 2 Technical Property 2 1 Accuracy a reading d...

Страница 13: ...age and polarity of the point where the red test lead is contacted will be displayed on the screen Caution 1 Don t measure voltage over 600V Otherwise there is a danger of meter being damaged 2 When m...

Страница 14: ...ion 600V DC or 600V AC Peak Value 2 2 2 ACV True RMS 1 Insert black test leads into the hole of COM and red one into 2 Rotate function switch to gear press SELECT button to select the AC measurement m...

Страница 15: ...voltage over 600V Otherwise there is a danger of meter being damaged 2 When measuring high voltage special attention should be given to personal safety and avoid your body getting in touch with high v...

Страница 16: ...nal Max 400mA or 10A input terminal Max 10A 2 Rotate function switch to Current gear The initiate state of the meter is in automatic range status which shows DC symbol Then connect the test leads to t...

Страница 17: ...The Max input value is 400mA or 10A Depending on the terminal where the red test lead is contacted Range Accuracy Resolution 400uA 1 0 10d 0 1uA 4000uA 1uA 40mA 10uA 400mA 100uA 10A 1 2 10d 10mA Max m...

Страница 18: ...switch to Current gear Press SELECT button to select the AC measurement mode Then connect the test leads to the tested circuit in serial the tested current value and the current polarity of the point...

Страница 19: ...he overrated current will lead to fuse melt or even damage the meter Range Accuracy Resolution 400uA 1 5 10d 0 1uA 4000uA 1uA 40mA 10uA 400mA 100uA 10A 2 5 15d 10mA Max measurement voltage drop Full R...

Страница 20: ...please short circuit the meter pens at first to test the wire resistance and then deduct it from the actual resistance Caution 1 If OL is displayed on LCD it indicates the tested resistance value has...

Страница 21: ...suring in line resistor be sure that the power is off and all capacitors are discharged completely Range Accur acy Resolution 400 0 8 5d 0 1 4k 0 8 4d 1 40k 10 400k 100 4M 1k 40M 1 2 10d 10k Open Volt...

Страница 22: ...pen to COM terminal and the red one to terminal The polarity of red test lead is 2 Rotate the Range to gear Press SELECT button to select the Diode measurement mode 3 Forward Measurement Connect the...

Страница 23: ...ing includes forward and backward measurement if the result does not meet the above it means the diode is bad 6 Press SELECT button to select the Continuity measurement mode 7 Connect the meter pens t...

Страница 24: ...pen circuit voltage is Approx 0 5V Overload Protection 250V DC or AC Peak Value CAUTION DO NOT INPUT VOLTAGE AT THIS RANGE 2 2 7 Capacity C 1 Rotate function switch to gear 2 Insert the black test lea...

Страница 25: ...ly discharge the tested capacitor in case it damages the meter 2 When measuring in line capacitor the power should be turned off and all capacitors should be discharged completely 3 It takes about 30...

Страница 26: ...COM terminals 2 Rotate function switch to Hz gear Connect test leads and the cable to the signal source or the tested load The tested signal will show on the screen Caution 1 When inputting AC RMS ove...

Страница 27: ...e frequency range 4 Don t input voltage of over 250V DC or AC peak value in case it damages the meter Range Accur acy Resolution 1Hz 0 5 10 0 001Hz 10Hz 0 01Hz 100Hz 0 1Hz 1kHz 1Hz 10kHz 10Hz 100kHz 1...

Страница 28: ...rminal Then put the working end temperature measurement end of thermocouple on the surface or inside the object to be tested Then you can read temperature from the screen and the data is in Centigrade...

Страница 29: ...0 5d 400 1 5 15d 1 4 1832 750 0 75 5d 750 1 5 15d 1 Sensor K Type Thermocouple Nickel chromium nickel silicon banana plug CAUTION DO NOT INPUT VOLTAGE AT THIS RANGE VII Instrument Maintenance This is...

Страница 30: ...magnetic place 3 Wipe the case with a damp cloth and detergent do not use abrasives and alcohol 4 If the instrument is not operated for a long time please take out the battery to avoid leakage 5 Pay...

Страница 31: ...lkaline batteries should be used 5 3 Mount the battery door and tighten the screw Precaution 1 Don t input voltage higher than DC 1000V or AC Peak Value 2 Don t measure voltage at current resistance d...

Страница 32: ...olve some general problems If the problems still exist please contact the maintenance center or the distributor Fault Solution No Display Turn on power Replace battery symbol appearance Replace batter...

Страница 33: ...e contact the manufacturer The Company shall not be held liable for any accidents and hazards resulted from the mal operations by the user The function elaborated by this Instruction shall not be take...