Note: When measuring ACV under auto range mode, pressing the RANGE key will display AC mV 
range. 
4. Connect the leads in parallel across the electric circuit under test, LCD displays voltage as measured 
by the test leads. 
Note: 
1. Operator should first set the selector knob to the highest range, if operator has no idea about the 
range of voltage under test, then select the proper range based on displayed value. If the LCD displays 

'

OL

'

, it means the meter is over the maximum value of this range, select a higher range. 

2

.

 Never input a voltage over 750VAC. 

3. Be careful while measuring a high voltage. DO NOT touch the high voltage circuit or leads. 
4-4. DCA measurement 
1.

 

Insert the black test lead into the 

'

COM

'

 terminal and the red one into the mA terminal (the Max. 

400mA) or into the 20A terminal (the Max.20A).  

2.

 

Use the selector knob and set to the proper DCA range, press the DC/AC key to select the 
measurement mode. Then, connect the leads in series into the electric circuit under test. LCD 
displays current under test. 

3.

 

When measuring mA DC through a control jack, use the FS01 adapter between the meter leads and 
the control jack. Insertion of leads into adapter is not important. If reading comes back as negative 
(

) leads are reversed. 

Note: 

1.

 

Operator should first set the selector knob to the highest range, if operator has no idea about the 

range of current under test, then select the proper range based on the displayed value . 

2.

 

If the LCD displays 

'

OL

'

, it means the current is over range. You need to move the selector knob to 

a higher range. 

3.

 

Maximum input current is 400mA or 20A based on the terminal the red test lead is inserted into, 

too large a current will damage the meter.  

4-5. ACA measurement 
1. Insert the black test lead into the COM terminal and the red one into the mA terminal (maximum 
400mA) or into the 20A terminal (maximum 20A). 
2. Use the selector knob to set the proper ACA range, press the DC/AC key to select the measurement 
mode, then connect the leads in series to the electric circuit under test. LCD displays current under test. 
Note: 

1. Operator should first set the selector knob to the highest range, if operator has no idea about the 

range of current under test, then select the proper range based on the displayed value. 

2. If the LCD displays 

'

OL

'

, it means the current is over range. You need to select a higher range. 

3. Maximum input current is 400mA or 20A based on the terminal the red test lead is inserted into, too 

large a current will damage the meter. 

4-6. Resistance measurement 
1. Insert the black lest lead into the 

'

COM

'

 terminal and the red lead into the 

'

V/

/Hz

'

 terminal. 

2. Turn the selector knob to 

 range. 

3. Connect the leads in parallel with the resistance being measured. 
3. Auto range is the original mode, press the RANGE key change to the manual range mode. 
4. When measuring the actual minimum resistance, short-circuit the test leads first, press the REL 
button and then test the resistance, it will now display the actual resistance. 
Note: 

Содержание VC88E

Страница 1: ...User s Manual for VC88E Digital Multimeter...

Страница 2: ...connection and the insulation of the test leads and probes to avoid electric shock 2 Never apply voltage higher than 1000VDC or 750VAC when measuring 3 Be careful when measuring a voltage higher than...

Страница 3: ...nse 2 4 DC Current DCA Range Accuracy Resolution 400uA 0 1 A 4000uA 1 A 40mA 10 A 400mA 1 0 5 100 A 20A 1 2 10 10mA MAX measurement voltage drop full range mA 1 2VA 100mV Max input current 20A within...

Страница 4: ...nce test Range Value displayed Testing condition Forward voltage drop of diode Forward DCA is approx 0 5mA the backward voltage is approx 1 5V Buzzer makes a long sound while resistance is less than 3...

Страница 5: ...uring function and range 4 Temperature positive and V Hz terminal 5 Voltage resistance frequency capacitor and temperature terminal 6 COM terminal 7 Less than 400mA current testing terminal and temper...

Страница 6: ...proper range based on the displayed value 2 If the LCD displays OL it means the current is over range You need to move the selector knob to a higher range 3 Maximum input current is 400mA or 20A base...

Страница 7: ...sert the black lest lead into the COM terminal and the red one into the V Hz terminal 2 Turn the selector knob to the Hz range 3 Place the test leads to the power source or the load which is to be tes...

Страница 8: ...the HOLD button again the HOLD function is cancelled 4 13 Auto power off 1 When the meter has not been used for about 15 minutes the built in buzzer will sound 5 times and the meter goes into sleeping...

Страница 9: ...ignal appears Replace battery Large Error Value Replace battery These specifications are subject to change without notice We hereby will not be responsible for any accident and damage caused by improp...

Отзывы: