27
VE414
9.
Remove the bleeder tube from the tee fitting
and tank. Install the plug back into the tee fit-
ting. Be certain air is not allowed back into the
tee fitting while doing this.
10.
Fill the hydraulic fluid level to
¹⁄₂
" from the
top of the tank and install breather.
11.
Set the depth stop on the tool to obtain a
¹⁄₄
" gap between the depth stop and cylinder.
12.
Set the valve on the power switch side of
the tool to the “black” position.
13.
Flip toggle switch to “Normal Operation”
position.
14.
Depress the foot switch and observe the
hydraulic ram motion. It should move down
¹⁄₄
"
fairly rapidly. Release the foot switch and the
hydraulic ram should return to its full up posi-
tion. Repeat this several times.
15.
Set the valve on the front of the tool to the
“red” position and repeat Step 14.
16.
If the slide does not move fairly rapidly in
the downward direction, repeat Steps 2 - 15.
17.
Set power switch to the “OFF” position.
GEAR REDUCER OIL LEVEL
CHECK
1.
Remove oil level plug from gear reducer (see
Figure 5). Oil level should be even with bottom
of hole.
Figure 5
2.
To add oil, remove oil fill/level plug from side
of gear reducer and fill to proper level (see Fig-
ure 5).
3.
Install plug(s).
GEAR REDUCERS OIL CAPACITY: 75 OZ.
• Lower roll will rotate during Step 14. Avoid contact
with lower roll.
Failure to do so may result in serious personal injury.
Vent Plug
Oil Level and
Oil Fill Plug