VD530 Series Inverter User Manual Function Parameter Table
- 85 -
A2 Motor 2 Parameters
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
A2-00
Motor Type
Selection
0: Common Asynchronous motor
1: Frequency conversion asynchronous
motor
0
◎
A2-01
Rated Motor
Power
0.1Kw~1000.0kW
Model
dependent
◎
A2-02
Rated Motor
Voltage
1V~2000V
Model
dependent
◎
A2-03
Rated Motor
Current
0.01A~
655.35A (Inverter power≤55kW)
0.1A~6553.5A (Inverter power>55kW)
Model
dependent
◎
A2-04
Rated Motor
Frequency
0.01Hz~max frequency
Model
dependent
◎
A2-05
Rated Motor
Rotate Speed
1rpm~65535rpm
Model
dependent
◎
A2-06
Asynchronous
Motor Stator
Resistance
0.001Ω~65.535Ω (Inverter
power≤55kW)
0.0001Ω~6.5535Ω (Inverter
power>55kW)
Tune
parameter
◎
A2-07
Asynchronous
Motor Rotor
Resistance
0.001Ω~65.535Ω (Inverter
power≤55kW)
0.0001Ω~6.5535Ω (Inverter
power>55kW)
Tune
parameter
◎
A2-08
Asynchronous
Motor Leakage
Inductive
Reactance
0.01mH~655.35mH (Inverter
power≤55kW)
0.001mH~65.535mH(Inverter
power>55kW)
Tune
parameter
◎
A2-09
Asynchronous
Motor Interaction
Inductive
Reactance
0.1mH~6553.5mH (Inverter
power≤55kW)
0.01mH~655.35mH(Inverter
power>55kW)
Tune
parameter
◎
A2-10
Asynchronous
Motor No-load
Current
0.01A~ A2-
03 (Inverter power≤55kW)
0.1A~A2-03 (Inverter power>55kW)
Tune
parameter
◎
A2-17
Encoder Line
Number
1~65535
2000
◎
A2-18
Encoder Type
0: ABZ incremental encoder
1: Rotary transformer
0
◎
A2-20
ABZ Incremental
Encoder AB
Sequence
0: Forward
1: Reverse
0
◎
Содержание VD530 Series