Function Parameter Table VD530 Series Inverter User Manual
- 82 -
A0-03
Max Frequency
Source
Selection under
the Torque
Control Forward
0: Digital setting (A0-04)
1: AI1
2: AI2
3: AI3 (expansion card)
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-04
Max Frequency
Digital Setting
under the Torque
Control Forward
0.00Hz~max frequency
50.00Hz
○
A0-05
Max Frequency
Source
Selection under
the Torque
Control Reverse
0: Digital setting (A0-06)
1: AI1
2: AI2
3: AI3 (expansion card)
4: PULSE
5: Communication setting
6: Keypad potentiometer
0
◎
A0-06
Max Frequency
Digital Setting
under the Torque
Control Reverse
0.00Hz~max frequency
50.00Hz
○
A0-07
Torque Control
Acceleration
Time
0.00s~650.00s
0.00s
○
A0-08
Torque Control
deceleration
Time
0.00s~650.00s
0.00s
○
A0-09
Starting Torque
Setting
0.0%~100.0%
10.0%
○
A0-10
Excitation
Current
Coefficient
under the Torque
Control (only
effective to SVC)
20.0%~150.0%
100.0%
○
A0-11
Low Frequency
Torque
Compensation
Amount
0.0%~50.0%
0.0%
○
A0-12
Low Frequency
Torque
Compensation
Frequency
Upper Limit
0.00Hz~Max frequency
10.00Hz
○