 Operation 

XX079-00-01 Rev 303 Video Switchers 

The sequence pattern programmed for each monitor in the EZ-A Sequence or EZ-B Sequence menu can be 
started or stopped without going into the programming menus. To start sequencing, first select the monitor, 
then press and hold the SHIFT key and press the START key. To stop sequencing, press any camera key 
number and the sequence will stop. Press and hold the SHIFT key and press the EDIT key to change the 
camera selection to the EZ menu. 
 

Sequencing Start: SHIFT, START 
Edit Camera EZ: SHIFT, EDIT 

 
The video switcher sequences cameras selected in EZ-A Sequence for Monitor A and sequences cameras 
selected in EZ-B Sequence for Monitor B.  

Alarm Functions 

The video switcher announces incoming alarms in several different ways, all of which can be enabled or 
disabled individually, except for status group display: 
 

Alarm list display on-screen 
Flashing power LED 
Buzzer 
Status group display “A” (always active) 

 
In addition to these local audible and visible announcements, a relay is available as a remote alarm output. 
 
All alarm annunciations except the buzzer can be acknowledge manually or automatically. The buzzer, if it has 
been enabled in the Setup Programming, must be acknowledged manually. 

The Alarm Display 

An alarm event may be announced on-screen with an alarm list display and codes displayed in the status 
group. The alarm list may be enabled or disabled, but the status group is always active. 

The Alarm List

 

If the alarm list has been enabled, an alarm event causes this message to be displayed in the lower half of the 
monitor screen: 
 

ACTIVE ALARM/FLASH-UNACK 
X Y Z 

 
where X, Y, and Z are camera numbers. The screen displays as many alarms as there are alarmed inputs. 
 
The alarm input number flashes until acknowledged. The acknowledgment occurs manually or automatically, 
depending on the state of Auto ACK in the Alarm submenu. Also, if any of the alarm inputs is active and Type 
in the Alarm submenu is in the Latched mode, then the alarm list flashes and continues to flash regardless of 
if the alarm input returns to an inactive state. The alarm list disappears from the screen either by auto or 
manual acknowledgment.  

Содержание VSW-16RS232

Страница 1: ...served Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631...

Страница 2: ......

Страница 3: ......

Страница 4: ...shield must be copper braid providing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical c...

Страница 5: ...cleaners 6 Attachments Do not use attachments not recommended by Vicon as they may cause hazards 7 Water and Moisture Do not use this video product in any location where it may be exposed to water or...

Страница 6: ...ords as this can result in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as they may touch dangerous voltage point...

Страница 7: ...ashing screen message and two contact relays On screen menus allow the user to easily program the video switcher using the front panel keys A real time clock allows programming for night weekend or ot...

Страница 8: ...for added contrast with the background Fourteen different screen arrangements of the time date camera title and monitor title are available The different screen displays allow the time date camera ti...

Страница 9: ...ing rack mounting and system cabling and setup programming Since it usually more convenient to complete the cable connections before rack installation those procedure are described first Rack installa...

Страница 10: ...VIDEO IN BNCs If the video is to be run to other devices such as a dedicated monitor or VCR or to a matrix switcher connect a coaxial cable from the desired VIDEO OUT BNC to the other equipment A ded...

Страница 11: ...standard termination boxes depending on the number of alarms required Each box can handle up to eight 8 alarms The unit can provide up to 32 alarms Alarm Inputs Hardwired alarms are carried over twist...

Страница 12: ...ers Figure 4 Termination Box Connections RS485 RS232 Connector This connector is not used at this time Rack Mounting The switcher is designed for mounting in an EIA standard 19 inch rack It requires 1...

Страница 13: ...ows REMOVE RUBOUT or BACK and ENTER Note To display the programming menu it is necessary to be connected to MON A When the unit is connected to a power source the following screen is displayed VICON I...

Страница 14: ...ged the video displayed on the monitor changes according to the camera input selected Note Any camera input can be accessed with this menu whether or not a camera is actually connected to the input Wr...

Страница 15: ...cial characters have an outline around them They are enabled by line E Char Outline of the Monitor Setup menu for the corresponding monitor A or B Monitor Setup Monitor setup involves writing a monito...

Страница 16: ...itle To view all available characters press either the up or down arrow keys continuously to scroll the entire character set through the window in the center of the screen SPECIAL CHARACTERS Included...

Страница 17: ...tion is in progress An alarmed channel remains in the alarm stack until it is acknowledged either manually or automatically but the A is displayed only while detection is taking place Selecting Charac...

Страница 18: ...ppears Seq Pattern 1 Index Camera Dwell 1 2 1 2 16 6 3 Unused 4 Unused 5 Unused 6 Unused Use To Scroll Index Enter Insert Camera Remove Deletes Camera Back Returns to Prev Index defines the sequence n...

Страница 19: ...tion or Time column Programming Alarms Bring the arrow cursor down to line D Alarms and press the right arrow key to display the Alarm Inputs setup menu Alarm Inputs A Return to Main Menu B Input Numb...

Страница 20: ...be programmed Lines F to I of the Alarm Inputs menu are associated with alarm output functions Alarm Inputs A Return To Main Menu B Input Number 01 C Input Enabled D Normally Open E Type Momentary F...

Страница 21: ...revious line of this menu it must be acknowledged manually It is unaffected by the auto acknowledge function Alarm List Display There are alarm announcements which include a list of active alarm chann...

Страница 22: ...starts the system clock To abort press BACK or RUBOUT Programming EZ A or B Sequence The selection of sequencing cameras for each monitor is done through line G the Edit EZ A Sequence menu for Monitor...

Страница 23: ...made while in secondary passcode The master passcode permits access to all menu items including line A and I of the Main Menu The secondary passcode can be customized for access to different programm...

Страница 24: ...ary Access menu Secondary Access A RTN To Passcode B Camera Setup C Monitor Setup D Alarms E Set Date F Set Time Edit EZ A Sequence Edit EZ B Sequence In the Main Menu an operator with a secondary pas...

Страница 25: ...locked Main Menu is displayed If the secondary passcode is displayed the blocked menu is displayed again and the operator may or may not be able to change settings in the menus of line B through F dep...

Страница 26: ...20 Programming XX079 00 01 Rev 303 Video Switchers Notes...

Страница 27: ...itcher is in the sequencing mode the selected video displays and stops the sequence A manual start must be initiated to resume sequencing If a camera that was selected in the EZ A or B Sequence is rem...

Страница 28: ...e and visible announcements a relay is available as a remote alarm output All alarm annunciations except the buzzer can be acknowledge manually or automatically The buzzer if it has been enabled in th...

Страница 29: ...m submenu The automatic acknowledgment mode is programmed in the Alarm menu and provides a dwell range from 1 to 60 seconds At the end of the programmed dwell period all forms of alarm output on scree...

Страница 30: ...Video Switchers Maintenance The 8 Channel and 16 Channel Series of Video Switchers require no regular maintenance Fuse Replacement The switcher has a 0 5 A fuse If it must be changed be sure to replac...

Страница 31: ...in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Nam...

Страница 32: ...figures are provided as an aid in determining the extent of cooling required for an installation Fuse 0 5 A 250 V 5 x 20 mm Line Cord Standard 3 conductor SV No 18 AWG cable with grounding plug VIDEO...

Страница 33: ...onnectors RS485 RS232 RJ 45 jack MECHANICAL Dimensions Height 1 7 in 43 2 mm Width 17 3 in 439 mm Depth 8 9 in 226 mm Weight 6 8 lb 3 1 kg Construction CRS Finish Black ENVIRONMENTAL Operating Tempera...

Страница 34: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...

Отзывы: