Vicon VSW-16RS232 Скачать руководство пользователя страница 22

16  

••••

 Programming 

XX079-00-01 Rev 303 Video Switchers 

A cluster of up arrows (the selection cursor) point at the date format. Use the up or down arrow key to select 
AMER, EURO, or ASIA. Then use the right or left arrow key to move the selection cursor to the first date 
position and enter the day, month, or year as determined by the format. Program all three date elements and 
the day of the week (WD). Press ENTER to set the date or press BACK or RUBOUT to abort. 
 
To set the time, select Set Time from the Main Menu to display the Set Time menu: 
 

          Set Time 
 
           HH:MM:SS 
TIME:  05:58:15AM 
           

↑↑

 

Use

↑↓

: To Change Digit 

Use 

←→

: To Select Digit 

 
  Enter: To Set Time 
     Back: To Abort 

 
The up arrow cursor is located under the hour position. In the example shown, AM is displayed at the end of 
the line. This indicates that 12-hour mode has been selected. To select the 24-hour mode, hold down the up 
arrow key until the AM and PM designations have disappeared. The lack of an AM or PM indicates that the 
time is now in the 24-hour mode. To set the time to the nearest second, set the minutes position to one or two 
minutes ahead of the reference clock and set the second to 00. When the reference clock reaches 00 
seconds of the specified minute, press ENTER. This starts the system clock. To abort, press BACK or 
RUBOUT. 

Programming EZ-A (or B) Sequence 

The selection of sequencing cameras for each monitor is done through line G, the Edit EZ-A Sequence menu 
(for Monitor A) or line H, the Edit EZ-B Sequence (for Monitor B). Also, the dwell time for all the cameras 
sequencing for Monitors A and B can be set from 1 to 60 seconds. To program the camera sequencing for 
each monitor, bring the arrow cursor to either line G or H (from the Main Menu) and press the right arrow key. 
A submenu is displayed (for Monitor A in this example) as follows. (Note that cameras 9 – 16 are only 
accessible on 16-channel units, even though the numbers appear on the menu for 8-channel units.) 
 
 

Edit EZ-A Sequence 
 
01   02   03   04   05   06   07   08 
XX   --   XX  XX  XX  XX  XX   XX 
 
09   10   11   12   13   14   15   16 
XX  XX  XX   XX  XX   XX  XX  XX 
Dwell:01 
 
Shift

↑↓

: To change dwell 

Shift 5: To exit 

 
The numbers 01 to 16 represents the camera inputs. Press the number key on the front panel for the 
associated camera input to toggle between XX or --. The XX symbol below the camera number indicates that 
the camera is selected as part of the sequence for Monitor A. The -- symbol below the camera number (in this 
example, camera 02) indicates that the camera is not selected as part of the sequence for Monitor A. The 
number to the right of Dwell indicates the switching time between cameras. The functional description for 
Monitor B’s menu is the same as Monitor A’s menu. 

Содержание VSW-16RS232

Страница 1: ...served Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631...

Страница 2: ......

Страница 3: ......

Страница 4: ...shield must be copper braid providing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical c...

Страница 5: ...cleaners 6 Attachments Do not use attachments not recommended by Vicon as they may cause hazards 7 Water and Moisture Do not use this video product in any location where it may be exposed to water or...

Страница 6: ...ords as this can result in a risk of fire or electric shock 17 Object and Liquid Entry Never push objects of any kind into this video product through openings as they may touch dangerous voltage point...

Страница 7: ...ashing screen message and two contact relays On screen menus allow the user to easily program the video switcher using the front panel keys A real time clock allows programming for night weekend or ot...

Страница 8: ...for added contrast with the background Fourteen different screen arrangements of the time date camera title and monitor title are available The different screen displays allow the time date camera ti...

Страница 9: ...ing rack mounting and system cabling and setup programming Since it usually more convenient to complete the cable connections before rack installation those procedure are described first Rack installa...

Страница 10: ...VIDEO IN BNCs If the video is to be run to other devices such as a dedicated monitor or VCR or to a matrix switcher connect a coaxial cable from the desired VIDEO OUT BNC to the other equipment A ded...

Страница 11: ...standard termination boxes depending on the number of alarms required Each box can handle up to eight 8 alarms The unit can provide up to 32 alarms Alarm Inputs Hardwired alarms are carried over twist...

Страница 12: ...ers Figure 4 Termination Box Connections RS485 RS232 Connector This connector is not used at this time Rack Mounting The switcher is designed for mounting in an EIA standard 19 inch rack It requires 1...

Страница 13: ...ows REMOVE RUBOUT or BACK and ENTER Note To display the programming menu it is necessary to be connected to MON A When the unit is connected to a power source the following screen is displayed VICON I...

Страница 14: ...ged the video displayed on the monitor changes according to the camera input selected Note Any camera input can be accessed with this menu whether or not a camera is actually connected to the input Wr...

Страница 15: ...cial characters have an outline around them They are enabled by line E Char Outline of the Monitor Setup menu for the corresponding monitor A or B Monitor Setup Monitor setup involves writing a monito...

Страница 16: ...itle To view all available characters press either the up or down arrow keys continuously to scroll the entire character set through the window in the center of the screen SPECIAL CHARACTERS Included...

Страница 17: ...tion is in progress An alarmed channel remains in the alarm stack until it is acknowledged either manually or automatically but the A is displayed only while detection is taking place Selecting Charac...

Страница 18: ...ppears Seq Pattern 1 Index Camera Dwell 1 2 1 2 16 6 3 Unused 4 Unused 5 Unused 6 Unused Use To Scroll Index Enter Insert Camera Remove Deletes Camera Back Returns to Prev Index defines the sequence n...

Страница 19: ...tion or Time column Programming Alarms Bring the arrow cursor down to line D Alarms and press the right arrow key to display the Alarm Inputs setup menu Alarm Inputs A Return to Main Menu B Input Numb...

Страница 20: ...be programmed Lines F to I of the Alarm Inputs menu are associated with alarm output functions Alarm Inputs A Return To Main Menu B Input Number 01 C Input Enabled D Normally Open E Type Momentary F...

Страница 21: ...revious line of this menu it must be acknowledged manually It is unaffected by the auto acknowledge function Alarm List Display There are alarm announcements which include a list of active alarm chann...

Страница 22: ...starts the system clock To abort press BACK or RUBOUT Programming EZ A or B Sequence The selection of sequencing cameras for each monitor is done through line G the Edit EZ A Sequence menu for Monitor...

Страница 23: ...made while in secondary passcode The master passcode permits access to all menu items including line A and I of the Main Menu The secondary passcode can be customized for access to different programm...

Страница 24: ...ary Access menu Secondary Access A RTN To Passcode B Camera Setup C Monitor Setup D Alarms E Set Date F Set Time Edit EZ A Sequence Edit EZ B Sequence In the Main Menu an operator with a secondary pas...

Страница 25: ...locked Main Menu is displayed If the secondary passcode is displayed the blocked menu is displayed again and the operator may or may not be able to change settings in the menus of line B through F dep...

Страница 26: ...20 Programming XX079 00 01 Rev 303 Video Switchers Notes...

Страница 27: ...itcher is in the sequencing mode the selected video displays and stops the sequence A manual start must be initiated to resume sequencing If a camera that was selected in the EZ A or B Sequence is rem...

Страница 28: ...e and visible announcements a relay is available as a remote alarm output All alarm annunciations except the buzzer can be acknowledge manually or automatically The buzzer if it has been enabled in th...

Страница 29: ...m submenu The automatic acknowledgment mode is programmed in the Alarm menu and provides a dwell range from 1 to 60 seconds At the end of the programmed dwell period all forms of alarm output on scree...

Страница 30: ...Video Switchers Maintenance The 8 Channel and 16 Channel Series of Video Switchers require no regular maintenance Fuse Replacement The switcher has a 0 5 A fuse If it must be changed be sure to replac...

Страница 31: ...in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Nam...

Страница 32: ...figures are provided as an aid in determining the extent of cooling required for an installation Fuse 0 5 A 250 V 5 x 20 mm Line Cord Standard 3 conductor SV No 18 AWG cable with grounding plug VIDEO...

Страница 33: ...onnectors RS485 RS232 RJ 45 jack MECHANICAL Dimensions Height 1 7 in 43 2 mm Width 17 3 in 439 mm Depth 8 9 in 226 mm Weight 6 8 lb 3 1 kg Construction CRS Finish Black ENVIRONMENTAL Operating Tempera...

Страница 34: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...

Отзывы: