background image

 

21

 

 

Technical Information   

 

 

SOFTWARE OPERATION 

Standard network protocol type 

using IP addressing scheme and 

separate PC application 

software.  

 

Camera can be setup using 

remote recorder or workstation 

GUI. Permissions can be 

assigned for macro create & 

edit, alarm setup, Authentication, 

Reports and System Status. 

 

System macros can be 

configured to use the camera’s 

video. In addition, within macros, 

alarms can be sent and remote 

macros run. 

 

An alarm can be triggered on 

video motion detection and loss. 

The alarm can be sent to remote 

units. 

 

The video from the camera can 

be set to view the Authentication 

status symbol (A) on the 

displayed video. 

 

Camera video can be setup to 

prioritize recorded picture quality 

and video FPS. Priority can be 

assigned to user/macro 

recording for highest requested 

video quality or Master user 

control. 

1/3-inch interline transfer CCD. 

 

 

NTSC: 768 (H) x 494 (V). 

PAL: 752 (H) x 582 (V). 

 

0.05 fc (0.5 lux). 

Conditions: lens at f/1.2 and   

25 IRE video output. 

 

480 lines. 

 

NTSC: 1/60-1/100,000. 

PAL: 1/50-1/100,000. 

 

NTSC standard: 2:1 interlace, 

525 lines, 30 frames/sec. 

PAL standard: 2:1 interlace,   

625 lines, 25 frames/sec. 

 

ON/OFF select. 

 

 

 

 

VIDEO CHARACTERISTICS 

 

24 VAC, ±10%.   

 

 

Internal fully isolated power 

input. 

 

500 mA nominal. 

 

12 W. 

 

0.7 btu/min (0.17 kg-cal/min). 

Note: These figures represent 

the conversion of 100% of the 

electrical energy to heat. Actual 

percentage of heat generated 

will be less and will vary from 

product to product. These 

figures are provided as an aid in 

determining the extent of cooling 

required for an installation. 

 

Refer to Table 2. 

 
 

FCC Class A. 

 

UL 2044. 

 
 
 
 

ViconNet Digital Video 

 Management System. 

 

100 Mbps, TCP/IP Unicast.

 

 

 

4, over LAN connection 

  (1 internal and 3 external). 

 

NTSC and PAL, model 

dependant. 

 

Divided among internal and 

external cameras. See Table 1. 

 

 

Maximum of 5 viewing/recording 

streams per camera. 

 

480 horizontal TV lines 

maximum at 640 x 480 pixel 

pallet (768 x 576, PAL). 

 

ViconNet software quality 1-8, 

selectable on an 8-position bar 

with 2 compression level settings 

in resolutions 640 x 480 (768 x 

576 PAL), 640 x 240 (768 x 288, 

PAL), 320 x 240 (384 x 288, 

PAL), 240 x 120 (288 x 144, 

PAL). 

 

 

1.5 Mbps (per video stream), 

nom.  

 

Refer to Table 3. 

 

Network Setup: 

 

 

 

 

Site Authorization: 

 

 

 

 

 

 

Macro Create & Edit: 

 

 

 

 

 

Alarm Setup: 

 

 

 

 

Authentication: 

 

 

 

Picture Quality and FPS 

Priority: 

 

 

 

 

 

 

Image Device: 

 

Active 

Picture Elements: 

 

 

Sensitivity: 

 

 

Horizontal 

Resolution: 

 

Electronic Iris: 

 

 

Scanning System: 

 

 

 

Backlight 

Compensation: 

 

 

 

Input Power Source: 

 

Input 

Power Isolation: 

 

Current: 

 

Power 

Consumption: 

 

Heat Equivalent: 

 

 

 

 

 

 

 

 

 

Maximum Power Cable 

Distance: 

 

Radio-Frequency 

Emission Standard: 

 

Safety Standard: 

 

 

 

Communication 

Platform: 

 

 

LAN Interface: 

 

Number of Video 

Channels: 

 

Video Formats 

Supported: 

 

Video Transmission 

Rate: 

 

Number of 

Simultaneous Video 

Streams: 

 

Video Transmission 

Resolution: 

 

 

Video Quality: 

 

 

 

 

 

 

 

 

 

Video Bandwidth: 

 

Hard Drive 

Consumption Rate: 

VICONNET (IP) 

ELECTRICAL 

 

Table 1 

Internal 
Camera

Number of 

External 

Cameras

FPS (Total)

1

0

30

1

1-3

15

Table 3 

60

200

300

500

600

900

1000

2000

3000

Days Recording

24

80

120

200

240

360

400

800

1200

Remote Hard Drive Storage (GB)

VN-755IP

Note: This table is based on the following conditions:                                                                                                                                                                                  

- 24 hours normal activity with 50% detected movement over time, Normal compression and Quality Q5 (320 x 240 pixels NTSC, 384 x 288 pixels PAL)                              
- Recording durations may vary based on actual scene activity.

 

 

 

XX156-00-01 Rev 705 VN-755IP Camera 

 

Содержание VN-755IP

Страница 1: ...be used for this purpose Warning To prevent fire or shock hazard do not expose the unit to rain or moisture Copyright 2005 Vicon Industries Inc All rights reserved Product specifications subject to ch...

Страница 2: ......

Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Страница 4: ......

Страница 5: ...door cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenn...

Страница 6: ...remove use a mild detergent and wipe gently 6 Never point the camera toward the sun Whether the camera is used outdoors or not never point it toward the sun Use caution when operating the camera in th...

Страница 7: ...ts the video over the ViconNet network When used as a single channel camera with no analog cameras connected the VN 755IP delivers up to 30 fps With the addition of 1 3 external connected there is a m...

Страница 8: ...or cable can be purchased separately as accessory kit Model No VN 755IP KIT product code 8775 To connect each sensor 1 Plug one end of the RJ 45 cable into the ALARM connector on the rear of the camer...

Страница 9: ...O and N C according to the equipment being installed Four 1K resistors are required and are included in accessory kit VN 755IP KIT which may be purchased separately To connect a microphone 1 Connect...

Страница 10: ...DC converter or the regulator inside the camera works properly 9 MODE SELECT SWITCH 1 FL flickerless ON OFF Switch This function is only used in Japan When set to ON the shutter speed is fixed at a r...

Страница 11: ...s a sunny day outdoors use an autoiris lens the EE ELC control range is not wide enough under these conditions 2 Under certain unique lighting conditions the following phenomena may appear Strong smea...

Страница 12: ...tial data value of V phase in EEPROM NOTE This camera offers V phase adjustment over a range of 180 If two or more cameras are connected to a switcher and the picture on the monitor rolls while switch...

Страница 13: ...Lenses 1 Install a lens and connect the camera to a monitor and power supply as described in this manual 2 Open the iris completely If an autoiris lens used reduce the room lighting to allow the lens...

Страница 14: ...5 Zoom out to the maximum wide angle setting If the picture is no longer in focus readjust the backfocus screw 6 Repeat steps 4 6 until the image remains sharp through the entire zoom range This compl...

Страница 15: ...attached SCSI RAID and integrated NAS SAN devices Refer to the network diagrams that follow for sample configurations Configuring ViconNet IP LAN The VN 755IP camera is shipped with two CDs VN 755IP...

Страница 16: ...12 XX156 00 01 Rev 705 VN 755IP Camera...

Страница 17: ...13 XX156 00 01 Rev 705 VN 755IP Camera...

Страница 18: ...ovided 2 Verify that the camera is physically connected to the network 3 Run the VNSetup application double click on VNSetup exe 4 Using the camera s MAC address select it from the TX Selection list S...

Страница 19: ...sion and press the Install button The IP camera will restart it will be unavailable for use for a few minutes 7 After the new version is successfully installed a confirmation message will display Vers...

Страница 20: ...Network Settings Window An Authorization screen is used to establish authority levels by user group Functions such as video view record and playback can be set for authority level A priority screen i...

Страница 21: ...ay Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit...

Страница 22: ...tance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables oth...

Страница 23: ...r RS 422 RS485 applications Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The max...

Страница 24: ...ications Choose a Belden cable type by referring to the characteristics listed below The Table below should be used as a guideline when cables other than Belden are used Materials and construction mus...

Страница 25: ...UL 2044 ViconNet Digital Video Management System 100 Mbps TCP IP Unicast 4 over LAN connection 1 internal and 3 external NTSC and PAL model dependant Divided among internal and external cameras See Ta...

Страница 26: ...Control Output for Autoiris External Controls Connectors CONTROLS AND CONNECTORS Better than 48 dB Automatic 1 0 V p p VBS 75 ohms composite video Line locking with vertical phase Automatic AGC ON OF...

Страница 27: ...e with policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may hav...

Страница 28: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...