Operation
When power is applied to the camera, the SVFT-MSH will boot up through a diagnostic routine and view the
currently selected scene. Refer to the SurveyorVFT Programming Manual for details on setup and operation.
Maintenance
The SVFT-MSH Camera Dome requires no scheduled maintenance except for the occasional cleaning of the
Lower Dome.
Care and Cleaning of Clear Acrylic Domes
1. Always handle the Lower Dome by the flange and avoid touching the inside surface.
2. If dust or dirt accumulates in the Lower Dome's interior, remove it with clean dry pressurized air.
3. If spots, streaks or stains appear on the exterior, they can be removed with a solution of mild soap or
isopropyl alcohol and water using a lint-free soft paper towel. Dry with clean, dry pressurized air.
4. Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft
cleaning cloth.
Caution:
Excessive rubbing of the Lower Dome surface can cause permanent scratches.
5. Clean all surfaces with any soft cleaning cloth and a mild glass cleanser suitable for acrylic plastic.
Fuse Replacement
Two fuses (F1 and F2) are located on the Communication/Power Supply Board of the Camera/Drive. When
necessary, replace them with the following Fuse values:
F1: 2AG, 1.6 amp, 250 volt, slo-blo
F2: 2AG, 2.5 amp, 250 volt, slo-blo
Note:
Refer to the SVFT Installation & Operation Manual for Camera Drive maintenance.
XX077-01-00 Rev 204 SVFT-MSH Maximum Security Housing
Operation
•
10