background image

Shipping Instructions 

Use the following procedure when returning a unit to the factory: 
 

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name 

of the Vicon employee who issued the R.A. 

 

Vicon Industries Inc. 
89 Arkay Drive 
Hauppauge, NY  11788 
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) 

 

For service or returns from countries in Europe, contact: 

 

Vicon Europe Ltd 
Brunel Way 
Fareham, PO15 5TX 
United Kingdom 
Phone: +44 (0)1489/566300; Fax: +44 (0)1489/566322 

 

2.  Attach a sheet of paper to the unit with the following information: 
 

a.  Name and address of the company returning the unit 

b.  Name of the Vicon employee who issued the R.A. 

c.  R. A. number 

d.  Brief description of the installation 

e.  Complete description of the problem and circumstances under which it occurs 

f. 

Unit’s original date of purchase, if still under warranty 

 

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 

4.  Mark the R.A. number on the outside of the carton on the shipping label. 

XX077-01-00 Rev 204 SVFT-MSH Maximum Security Housing 

Shipping Instructions  

  11 

Содержание SVFT-MSH18

Страница 1: ...em has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2004 Vicon Industries Inc All rights reserved Product specifications subject to change w...

Страница 2: ......

Страница 3: ...n 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 10 MAINTENANCE 10 Care and Cleaning of Clear Acrylic Domes 10 Fuse Replacement 10 SHIPPING INSTRUCTIONS 11 CABLE RECOMMENDATIONS 12 Coa...

Страница 4: ...Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N XX077 01 00 Rev 204 SVFT MSH Maximum Security Housing Quick Installation 2...

Страница 5: ...wer Dome assembly and mounting studs for the SurveyorVFT Camera Drive In addition the housing provides outside holes for external mounting brackets and tamperproof hardware for Lower Dome removal Unpa...

Страница 6: ...ersion 18x zoom high resolution camera variable speed camera dome aluminum upper housing with lower acrylic dome mounting bracket not included SVFT MSH18C 8712 01 1 4 in color camera PAL version 18x z...

Страница 7: ...Figure 1 Exploded View XX077 01 00 Rev 204 SVFT MSH Maximum Security Housing Introduction 5...

Страница 8: ...t is recommended to use four 3 8 in 9 5 mm diameter lag type screws or bolts with lock and flat washers Choose one of the two available four 4 hole mounting patterns Lift the Housing to the Mounting B...

Страница 9: ...SIGNAL NAME BNC female VIDEO J1 J1 VIDEO Video output AMP Header J2 J2 Fiber Optic board Video RS 422 data TERMINAL BLOCK POWER TB1 TB1 1 H Hot TB1 2 N Neutral TERMINAL BLOCK ALARM TB2 TB2 1 ALARM 1...

Страница 10: ...3 ALARM 2 Alarm input 2 TB2 4 GND Ground TB2 5 ALARM 3 Alarm input 3 TB2 6 GND Ground TB2 7 ALARM 4 Alarm input 4 TB2 8 GND Ground TERMINAL BLOCK COMM RELAY TB3 TB3 1 COMM IN Command in TB3 2 COMM IN...

Страница 11: ...M 3 Alarm input 3 TB2 6 GND Ground TB2 7 ALARM 4 Alarm input 4 TB2 8 GND Ground TERMINAL BLOCK RELAY TB4 TB4 1 RELAY C Relay common TB4 2 RELAY NO Relay normally open TB4 3 RELAY NC Relay normally clo...

Страница 12: ...n be removed with a solution of mild soap or isopropyl alcohol and water using a lint free soft paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior may be r...

Страница 13: ...d Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon empl...

Страница 14: ...ired picture quality and cable distance to provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refe...

Страница 15: ...venient for RS 422 RS485 applications Single twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distanc...

Страница 16: ...IP 1 8 A Power Coax Fiber UTP 35 W ViconNet TCP IP 45 W Heat Equivalent Coax Fiber UTP 2 0 BTU min 0 5 kg cal min ViconNet TCP IP 2 6 BTU min 0 64 kg cal min Note These figures represent the conversi...

Страница 17: ...ur Capabilities 22X 23X Versions 2 autotours available with 256 pan tilt and zoom functions per autotour Programming is done in real time with joystick and push buttons Autotours not available on 18X...

Страница 18: ...n RS 422 RS 485 mode Pan tilt 0 125 zoom 0 125X Competitive Protocols DIP Switch selectable Available in coaxial and UTP versions only Protocols are Pelco Pelco D Protocol 3 2 99 RS 485 N 8 1 simplex...

Страница 19: ...Clear Acrylic impact resistant Dimensions See Table 8 and Figure 3 Configuration Width W in mm Height H in mm Depth D in mm Housing Alone 11 8 300 10 0 254 11 7 297 Wall Mount 12 2 310 10 0 254 14 6 3...

Страница 20: ...Range 100 relative humidity Storage Temperature Range 40 to 150 F 40 to 65 C Storage Humidity Range Up to 90 relative noncondensing Ingress Protection EN60529 IP 65 rated Wind Load 90 mph using option...

Страница 21: ...NOTES XX077 01 00 Rev 204 SVFT MSH Maximum Security Housing Technical Information 19...

Страница 22: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712...