Wiring
|
3-9
Position 4 – Unused (set to OFF)
Position 5 – Unused (set to OFF)
Position 6 – Set NTCIP. OFF = Default Position, NTCIP Enabled.
ON = NTCIP disabled.
Position 7 – Set password. OFF = Default Position. ON = Reset to
default password (
password or 1234
); must be reset to OFF after
reboot and before next power up.
Position 8 – System Mode. OFF = Default Position, ViconNet Mode.
ON = ONVIF/NTCIP Mode.
The main board is located underneath the housing. It may be necessary to
spin the housing mechanism to see the DIP switch, located near the tilt motor
along edge of the board.
DIP Switch Location on Main Board
Communication Ports
If using NTCIP protocol, communicate to the Surveyor HD using ports
3000/UDP or 3001/TCP.
If using ONVIF, use port 8000.
Surveyor HD Network Dome