50
•
Getting to Know ViconNet
XX128-33-00 Rev 806 Kollector Pro Network Digital Video Recorder
Column Description
Remote Time
The time at the remote location where the alarm event occurred.
NOTES:
•
If the alarm occurred locally or at a site in the same time zone, the
local time and remote time will be identical.
•
If the alarm occurred at a remote site in a different time zone, the
local time will display the local time zone translation of the remote
time.
Example:
If the alarm occurred in London at 0700, and the display you are
looking at (the nucleus) is in Eastern US, the remote time displayed is
0700 and the local time is 0200.
Site Name
The name of the Kollector Pro.
Activations
Number
Indicates the number of times an alarm has been activated on the specific
device within a specific time period.
Each time the alarm is activated, another alarm event line is added to the alarm
history for that device (except in the case of a re-activation, as described
below).
In cases where the alarm was activated and then re-activated within a very
short period of time afterwards, the re-activation of the alarm is
not
displayed in
the alarm history.
Unite Alarms
which occur
within …
The time interval that passes after an initial alarm, in which movement will not
trigger a new alarm, but will cause an increment of +1 in the
Number of
Activations
field. This is useful if there is a lot of movement, and you do not
want to continuously activate new alarms.
NOTE:
In the Alarm Setup window, the value in the field
Min time between
alarms
field determines how much time must pass after the first and
subsequent alarms before a new alarm is generated (for a specific
camera).
The difference between
Min time between alarms
and the
Unite
Alarms which occur within…
, is that the
Min time between alarms
field defines that an alarm is not generated within a certain time,
where as the
Unite Alarms which occur within…
field determines
which alarms are combined as additional activations of the last alarm.
Example:
Minimum time between alarms
= 1 minute
Unite alarms which occur within
= 2 minutes
If alarms are continuously being generated, a new line only appears
in the Alarms pop up screen after one minute has passed. If an alarm
occurs between one and two minutes after the former alarm, it is
added to the previous alarm's data (existing row) as an additional
activation. If
Unite alarms which occur within...
is smaller than
Minimum time between alarms,
the number of activations is always
one, and each alarm generates a new row (alarm.)