SETTING UP YOUR WARM MIST HUMIDIFIER
• Remove packaging materials. Keep this Instruction Manual for
reference.
• Remove twist tie from power cord and extend power cord full
length.
• Ensure Proper Assembly. Make sure Mist Chimney, Medicine Cup,
and Water Tray are securely in place and that Heating Element Cover
is secured. See Reassembling instructions for reference.
• Place humidifier on a firm, level, water resistant surface a minimum
of 30 cm from walls. Steam should be directed away from any walls,
bedding, or furniture (See fig. 1- page 2).
Warning : keep out of reach of children. This product produces
hot steam and should be placed in an area not accessible to
children or pets, with the power cord out of reach.
FILLING / REFILLING
NOTE: WATER TANK SHOULD BE CARRIED USING TWO HANDS; ONE HAND
ON THE TANK HANDLE AND THE OTHER SUPPORTING THE BOTTOM OF
THE TANK.
Helen of Troy will not accept responsibility for property damage caused
by water spillage.
• Remove Water Tank by grasping Handle and pulling up. Remove
Tank Cap by turning counter clockwise. (to left) (See fig. 2 - page 2).
• Fill Tank with cool water. DO NOT fill with warm or hot water.
DO NOT ADD ESSENTIAL OILS, MEDICATIONS, OR INHALANT LIQUIDS
IN THE WATER TANK. Doing so could cause damage to the humidifier
and void the warranty (See fig. 3 - page 2).
• Replace Tank Cap by turning clockwise (to right) to screw back in
place. DO NOT over-tighten. Place Tank back on humidifier Base
(See fig. 4 - page 2).
RESETTING WHEN RESET LIGHT ILLUMINATES
When your humidifier is out of water, the Reset Light will illuminate.
To reset:
• Turn power OFF (
)
• Refill and replace Water Tank.
• Wait 5 minutes and turn power ON (
)
Note: If Reset Light (
) is still on, clean Heating Element
(see cleaning instructions)
USING YOUR HUMIDIFIER
• Power: With the Power Knob in the OFF position ( ), Plug the
filled humidifier into a suitable mains outlet. Make sure the voltage
in your home corresponds to the voltage marked on the device.
CAUTION: To avoid electric shock, DO NOT plug in humidifier with
wet hands.
• Output: Turn Power Knob to high (
) or low ( ). A green light will
indicate the humidifier is working, but it will take 3-4 minutes for
visible steam to appear.
• Humidity Level: Once a comfortable humidity level has been
reached, turn to the low setting. A comfortable humidity level is
between 40-60%.
Consider using a humidity monitor such as the recommended by
Vicks V70 Hygrometer & Thermometer to display current room
humidity and temperature. If condensation forms on walls,
windows, or around unit, turn humidifier off; the humidity level is
too high.
CAUTION:
Hot steam
CAUTION: TURN HUMIDIFIER OFF, UNPLUG AND WAIT
20-30 MINUTES FOR UNIT TO COOL BEFORE MOVING OR
CLEANING. DO NOT OPERATE YOUR HUMIDIFIER WITHOUT THE
TANK IN PLACE OR IF THE UNIT IS EMPTY. DO NOT OPERATE
YOUR HUMIDIFIER WITHOUT THE MIST CHIMNEY, WATER
TRAY, HEATING ELEMENT COVER, OR INHALANT CUP PROPERLY
ASSEMBLED.
VH845 ACCESSORIES
The following accessories work great with your humidifier.
These accessories can be purchased at most major retailers.
VapoPads Scent pad can be used to provide soothing menthol (VH7) or
lavender/rosemary (VBR7) vapors. (One complimentary menthol scent
pad included with product)
Hygrometer (V70EMEA) enables you to monitor the
humidity level & room temperature to ensure you
maintain a 40-60% humidity rate thus reducing the
survival of flu viruses on surfaces and in the air.
The Protec™ Antimicrobial Cleaning Product
(TWT001EU) features an antimicrobial, Aquastat
®
,
that helps keep your humidifier cleaner, longer.
Simply drop in the tank for fresh, clean mist!
Benefits of using these products include:
• Kills up to 99% of odor causing bacteria
• Keeps cleaning for 30 days
• Contains no harmful chemicals
Use only with
VapoPads Rosemary & Lavender
(VBR7) or Menthol (VH7)
+
36m
*
ENG
LISH
IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before starting to use the
appliance. Keep this manual in a safe place for future reference.
These instructions are also available on our website.
Please visit www.helenoftroy.com.
WARNING:
The vapour emitted from
this appliance is hot, please take care when
the appliance is in operation
WARNING:
Unplug the appliance during filling
and cleaning
• Keep out of reach of children.
• The appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
this appliance in a safe way and understand
the hazards involved. Children shall not
play with the appliance. Cleaning and user
maintenance shall not be made by children
without supervision.
• Do not operate the humidifier outdoors.
• Place the humidifier on a level, firm, heat-
resistant, non-metallic and waterproof
surface. Make sure it is in a stable position,
so that it cannot fall over or fall down.
Water can damage furniture and floors.
Helen of Troy will not accept any
responsibility for property damage caused
by water spillage.
• Unravel the power cord before use. Failure
to do so could cause overheating and
possible fire hazard.
• Do not use an extension cord. Doing so
could cause overheating, fire hazard or
electric shock.
• Only connect the humidifier to a single-
phase AC supply to the voltage shown on
the rating plate.
• Always disconnect power cord at wall plug
and allow the humidifier to cool down for
at least 30 minutes, before removing the
unit, filling, touching, moving, cleaning
or when not in use. Some parts can get
hot. Do not pull on the power cord when
disconnecting it.
• Do not add any substances into the water
tank or heating chamber (e.g. inhalant,
aromatic substances etc.). This can cause
health hazards to people and can cause
overheating, fire hazard, potentially void
warranty.
• Do not direct the steam outlet directly at
people, walls or any objects.
• Do not touch the steam. Steam can cause
burns.
• Do not remove the water tank or the
cooling chamber during operation or within
30 minutes after the humidifier is turned
off and unplugged.
• Do not immerse the humidifier in water
or other liquids and do not pour water or
other liquids over the humidifier or into the
steam outlet.
• Ventilate the room regularly. When a
humidifier is used in closed or small rooms,
excessive humidity can cause condensation
on walls and windows.
• Clean the humidifier regularly and follow
the “Cleaning Instructions”.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
• Do not operate the humidifier if it is
damaged, faulty or is not working properly.
Disconnect it from the electrical supply.
HOW IT WORKS:
The Warm Mist Humidifier is designed to quietly provide visible warm
mist. The tank feeds water into the boiling chamber where it is heated
to a steam vapor. The steam vapor mixes with dry air in the mist
chimney and warm moist air is released into the room.
COMPONENTS
(See page 1)
1 Inhalant Cup
2 Mist Chimney
3 Reset Light
4 Power Knob
5 Heating Element
6 Heating Element Cover
Содержание WarmMist VH845E