Vicking electronics
Pag. 4
Barcode port 1
Right DIN connector
In the default setting the right and left DIN connector gives the
same software code, so the user can choose where he plugs in
the barcode reader.
Left DIN connector
Can be programmed to give a different software code as the
right connector if the application demands it.
Barcode port 2
Internal molex connector Can’t be used if the left DIN connector is also used.
This connector is used if you want to prevent the user from
easily disconnecting the barcode reader.
Proximity / magnetic card readers
The workmate can read magnetic cards that have data on track2
in accordance with the international standard ISO 2 ABA.
Character encoding: 4 bits plus a parity bit.
Track encoding: START(13) DATA END(15) LRC maximum 38 characters.
The magnetic card readers and the proximity readers both use the same protocol and the same connectors,
but some connections are reserved only for proximity.
There are 2 ways to connect a magnetic card reader to the WORKmate:
Prox. port 1
Internal molex connector If the reader must be permanently connected to the
WORKmate.
Prox. port 2
Left DIN connector
The installation is easier through this connector, but can be
disconnected by the user.
Both connections can be used at the same time.
There are 4 ways to connect a proximity reader to the WORKmate:
Internal proximity reader A proximity module can optionally be mounted directly on the
WORKmate mainboard.
Prox. port 1
Internal molex connector To connect to an internal proximity board. Or an external
proximity reader a short distance from the WORKmate that
can’t be disconnected easily.
Left DIN connector
You can connect an external proximity reader a short distance
from the WORKmate via the left DIN connector.
Prox. port 2
Opto-coupled interface
on the I/O board
If you want to connect an external proximity reader a long
distance from the WORKmate you need to install the extra I/O
board.
Both port can have a reader connected at the same time.
Like the barcode readers, you can setup the ports to generate the same or a different software code.
Input / Output
Each DIN connector has one output pin. These outputs are not buffered with a relays, they are directly
connected to the WORKmate transistors. These outputs are used in special interfaces connected to the
WORKmate.
You need the I/O board if you want more powerful outputs.
Each DIN connector has an input pin, you must connect a switch to these inputs (from ground pin 2 to the
input pin 7). The inputs are only meant to detect if a switch in on or off. Do not connect an external voltage to
the input pins. You need the I/O board if you want more powerful inputs.