Avoid One Sided Weight 

 

VT027 is designed for user to evenly distribute the body 
weight on both sides of the platform.   
 

 

 
If user puts the entire body weight on a single side of the 
platform, the load on the motor is doubled.   
 
A  protection  program  is  built  in  to  prevent  motor  from 
overloading.  If  a  user’s  entire  weight  is  on  one  side  of 
platform,  the  motor  will  run  faster  to  generate  more 
power  to  adapt  to  the  increased  load.  This  is  called 
speed  compensation,  which  protects  the  motor  and 
extents the life of the machine. 
 
We  don’t  recommend  user  to  constantly  put  the  entire 
body weight on only side of the machine. 
 
The designed maximum load of VT027 is 120 KB / 264LB. 
Overload can damage the machine. 
 

G-force of VT027 

 
G-force is an acceleration rate expressed in units of G 

(the acceleration of gravity). G-force is determined by the 
vibration  frequency  and  amplitude,  it  is  an  important 
vibration intensity indicator. The maximum empty load G-
force calculated for VT027 is 2.97. 

 

For more information about our formula and conditions 
about  vibration  G-force  calculation,  please  visit  our 
website 

www.VibrationTherapeutic.com

 
 
 
 
 
 
 
 
 
 

Troubleshooting 

 

Remote control does not work 

Remote  control  needs  to  point  at  the  remote  signal 
receiving window on the control panel to work. 

The  distance  from  the  remote  control  to  the  control 
panel should not exceed 4 ft. 

Remote control can run out of battery in a couple of 
years. 

 

The control panel display windows do not light up 

Check if the power switch at the back of the machine 
is turned on.   
Or,  check  if  the  fuse  is  broken.  Fuse  box  is  located 
between the power switch and the power cord socket. 
Use a flat-headed screwdriver to remove the 
fuse box cap and remove the fuse and check. 
If fuse is broken, replace it with a 5A /125V 
fuse. 
 
If  the  replaced  fuse  breaks  again,  it  is 
possible the control box is defective. Please 
contact the seller for warranty service. 

 

The  power  is  off,  but  the  display  LED  light  up  when 
step on the machine 

This is normal. The motor rotation generates induction 
electricity that light up the display LED light. 

 

After power off, the display LED is still on for a while 

This is normal. It is the discharge of electricity stored 
in the circuit.   

 

 

VIBRATION  THERAPEUTIC®  represents  high 
quality vibration  plate  machines  that  SpecsPro  LLC 
develops and delivers to the global market. 
 
SpecsPro LLC 
Minneapolis – Shanghai 

[email protected]

 

www.VibrationTherapeutic.com

 

Содержание VT027

Страница 1: ...erson responds differently to vibration frequency amplitude and movement pattern Vibration therapy may not work for everyone We are passionate about promoting vibration therapy however any health bene...

Страница 2: ...the upper body If you are new to vibration machine please start with low frequency and low amplitude You can gradually increase the frequency after you get used to the vibration and start to enjoy the...

Страница 3: ...xcept for attaching a pair of handles or a pair of resistance bands that are designed for arm and upper body exercises There is no maintenance needed over the lifetime of the machine Place the machine...

Страница 4: ...istance Bands If desired you can attach the pair of resistance bands designed for arm exercises Below illustration shows how to attach the resistance bands to the machine 1 Turn slide out the metal la...

Страница 5: ...isplays the programmed speed level Middle Window Remote Control Receiver This window receives remote control signal The remote control uses infrared light signal to transfer orders therefore it needs...

Страница 6: ...witch on the back If there will be a long time not using the machine turn off the power switch Manual Control Mode At manual control mode displayed as P0 user can manually set up session time and adju...

Страница 7: ...eutic com Troubleshooting Remote control does not work Remote control needs to point at the remote signal receiving window on the control panel to work The distance from the remote control to the cont...

Отзывы: