![Vibration Therapeutic VT027 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/vibration-therapeutic/vt027/vt027_user-manual-and-tech-specs_1012344006.webp)
Operation Instruction
1. Power on the machine pressing the main power
switch at the backside. The control panel will light up.
Each time the machine is powered on, the default
mode is manual control Po, and the default session
time is 10 minutes.
2. Use P button on the control panel or the remote
control to select manual mode P0 or program mode
P1, P2 or P3.
3. Use Time button on the control panel or Time+ or
Time- buttons on the remote control to set up session
time. Session time can be set up between 1 minute
and 20 minutes, only in manual mode.
In program mode P1, P2 or P3, session time is preset
at 10 minutes, and cannot be changed. Session time
can only be change in manual control mode P0.
4. Once the program and time are set up, press Play /
Stop button on either control panel or remote control
to start the vibration session.
5. When the machine is running on manual mode (P0),
you can adjust the speed level from 1 to 20.
It is highly recommended for new users to start with low
speed level. You can gradually increase the speed as
you feel comfortable and enjoy the benefits.
After each use, user can press the Standby button on the
remote control to turn off the machine. No need to turn
off the power using the power switch on the back. If there
will be a long time not using the machine, turn off the
power switch.
Manual Control Mode
At manual control mode (displayed as P0), user can
manually set up session time and adjust speed. Each
time the machine is powered on, the default session time
is 10 minutes, and default speed level is 1.
Session time can be set up only when the machine is
idle. The session time can be set up between 1 minutes
and 20 minutes.
Speed level can only be adjusted when the machine is
running on manual mode. The speed level range is from
1 to 20. The table below shows the relationship between
speed level and vibration frequency (Hz).
Speed
1
2
3
4
5
6
7
Hz
5
5.5
5.9
6.4
6.9
7.4
7.8
Speed
8
9
10
11
12
13
14
Hz
8.3
8.8
9.3
9.7
10.2
10.7
11.2
Speed
15
16
17
18
19
20
Hz
11.6
12.1
12.6
13.1
13.5
14.0
Program Mode
Programs are designed to provide different movement
patterns of speed change, which create a spectrum of
stimulation to your muscles, bones, tendons, ligaments
and nerves.
Three programs are built in. Each program runs a set of
speed levels that change every minute, for a total 10
minutes session.
P1: Low intensity spectrum
P2: High intensity spectrum
P3: Mixed intensity specturm
Speed Level
P1 16 18 12
8 18 10 15
6 12
8
P2 20 20 15 18 20 16 20 10 20 15
P3 10
4 20 12 20 10 20
6 20 14
P0
Manual control speed level
Time buttons and Speed buttons are disable when the
machine is running on program mode.