MPOLx-84/85 (P)
79
9 P
ROBE
/PCM O
PERATION
S
ELECTING
A
PROFILE
AND
ADAPTER
/
TIP
To show/hide the focus quality bar:
1.
Press the
[
A
]
key.
2.
Tap the
[
More
]
button.
3.
Tap
[
PCM Settings
]
or
[
Probe Settings
]
.
4.
Tap
[
Show Focus Quality
]
to show/hide the bar.
Selecting a profile and adapter/tip
About profiles
Profiles contain the analysis parameters from which pass/fail
criteria are determined. A number of profiles are supplied with
the instrument. Profiles cannot be created in the instrument but
with the FiberChekPRO™ software and transferred to the
instrument via remote control. Information about creating
profiles can be found in the FiberChekPRO™ user manual.
To select a profile:
1.
Press the
[
A
]
key.
2.
Tap the
[
Profile
]
button.
3.
Tap the desired profile.
About adapters/tips
When trying to select an adapter (PCM) or a tip (probe) only
these adapters/tips are presented that are supported both by
the selected profile and the camera in use. Therefore the profile
must be selected prior to the adapter/tip.
Depending on the selected adapter/tip, the camera's
illumination LED is set to a precalibrated brightness stored in the
camera's memory.
Table. 1 Examples for profiles stored in the instrument by default.
Profile
Pass/fail criteria for ...
E2000
... precision metal ferrule connectors
MM_
.. multi-mode connectors from IEC 61300-3-35
Ribbon_
... single- and multi-mode connectors from IEC 61300-3-35
SFP_
... small form-factor pluggables
SM-UPC
... single-mode UPC connectors from IEC 61300-3-35
SM-APC
... single-mode APC connectors from IEC 61300-3-35
SM_PC
... single-mode PC connectors from IEC 61300-3-35