Seeker X User’s Guide
22137808, Rev. 001
Feb 2020
54
Chapter
3 Leakage Testing
Before you begin leakage testing
y
A low battery may cause the Seeker X to NOT turn on. Try charging your battery for 3
hours to see if that fixes the problem, or use the Seeker X while in the Mobile Mount.
y
The Seeker X will retain the setup from when the meter was last shut off. For example,
if you were testing frequency preset number two and then turned off your Seeker X,
when you turned it back on again the meter would automatically begin testing that
same preset.
Testing for leaks
The Seeker X should be configured with the Seeker Setup software before beginning leakage
testing.
NOTE:
Unless OFDM leakage detection is used, the CT-X Digital
Channel Tagger must be installed and set up within the
system before testing for leaks.
NOTE:
For more information about using the Preset Frequency or
Channel Tag features, see
Chapter 2: “Using Your Seeker X”
.
1. Turn on the Seeker
X.
Press the
POWER
button until you hear 3 ascending tones. The Seeker X will power up
in RF Level Measurement mode.
2. Confirm the desired frequency preset (1–4) is selected.
If using the Seeker X for the first time, the default frequency preset during
configuration with Seeker Setup software will be selected.
If the Seeker X has been used since configuration with Seeker Setup software, the last
frequency used will be selected.
3. Confirm the Seeker is in the RF Level Measurement mode.
The Antenna icon on the display should be flashing for the RF Level Measurement mode.
If necessary use the
SELECT
button
to move to the Measurement mode.
Содержание Seeker X
Страница 1: ...Seeker X Digital Leakage Detection System User s Guide ...
Страница 6: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 6 ...
Страница 10: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 10 Contents ...
Страница 18: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 18 About this Guide ...
Страница 32: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 32 Chapter 1 Quick Tour ...
Страница 52: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 52 Chapter 2 Using Your Seeker X ...
Страница 56: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 56 Chapter 3 Leakage Testing ...