Front panel 

2.2.1 

Front panel, visual indicators 

The  summary  alarm  plug-in  module  has  three  front  panel  LEDs  for  indication  of  the  state  of  the  module.    The  following  table  shows  the 
operation of the front panel LEDs which are dependent on module type. 
 
 
 

 

Colour

 

Status 

LED1

 

GREEN

 

Normal 

No light 

No power 

LED2

 

GREEN

 

LOAD ON (Any load resistor active) 

No light 

LOAD OFF 

LED3

 

GREEN

 

Normal 

Solid

 RED

  

ALARM, acknowledged  

Flashing 

RED

 

ALARM, active 

 
 

2.2.2 

Front panel, reset switch 

The hard reset switch is accessible via a small hole behind the handle.  Under all normal operating circumstances it should not be required.  
Actuating the hard reset will cause the module to reboot, the rack inventory table will be deleted. 
 

2.2.3 

Front panel, buzzer  

The  summary  alarm  plug-in  module  has  a  front  panel  mounted  buzzer  for  indication  of  the  modules 
state.  The following table shows the operation of the buzzer. 
 
 
 
 

Buzzer

 

Status 

OFF 

No ALARM or ALARM acknowledged 

ON 

ALARM active 

 
 
The buzzer operates with a nominal frequency of 2.4kHz, the tone is modulated. 
 
 

2.2.4 

Front panel, acknowledge switch  

The ACKNOWLEDGE switch is housed on the front panel, this is used to acknowledge alarms.  It works in a number of different modes after 
the alarm is generated depending on the status of the slot module when the acknowledge switch is hit. 
 
After the ACKNOWLEDGE switch is pressed the summary alarm card will continue to monitor for further alarms. 

 

Front panel, acknowledge switch, slot alarm active, with I2C response, fail module 

In  this  state the summary  alarm module  assumes that  a  faulty module is  fitted  in the slot.   After  pressing  the  ACKNOWLEDGE switch  the 
BUZZER  is  MUTED  and  the  STATUS  LED  is  in  ALARM  acknowledged  state  (see  section  2.2.1).  The  status  of  the  relays  remains 
unchanged. 

 

Front panel, acknowledge switch, slot alarm active, with no I2C response, removed module 

In this state the summary alarm module assumes that a faulty module has been removed.  After pressing the ACKNOWLEDGE switch the 
BUZZER is OFF and the STATUS LED is in normal state (see section 2.2.1).  The relay will be in its normal state. 

LED1 

LED2 

LED3 

Buzzer 

Reset 
Switch 

Acknowledge 

Switch 

Содержание HRC-2-HB-5

Страница 1: ...e User Guide HRC 2 HB 5 CR4645 10 12 2020 Pulse Power Measurement Ltd 65 Shrivenham Hundred Business Park Watchfield Swindon Wiltshire SN68TY UK Tel 44 0 1793 784389 Fax 44 0 1793 784391 Email sales vialite com Web www vialite com ...

Страница 2: ...e Precautions for handling electro static sensitive devices should be observed when handling all ViaLiteHD modules Technicians should ensure that they use effective personal grounding i e ESD wrist strap etc when servicing the equipment Any equipment or tools used should be grounded to prevent static charge build up Good practice should be observed at all times for reference see relevant standards...

Страница 3: ...eplaced module 8 Front panel acknowledge switch slot alarm inactive with no I2C response fail module 8 Rear panel 8 2 3 1 Rear panel module rear connections 8 2 3 2 Rear panel backplane relay connection 8 User configuration DIP switches 8 2 4 1 User configuration DIP switches alarm masking SW2 and SW3 9 2 4 2 User configuration DIP switches load resistors SW5 10 3 SETTING UP THE SUMMARY ALARM MODU...

Страница 4: ...e The CPU monitors all rack alarm outputs Compatible with either 1U or 3U rack The CPU controls all module outputs The module fits in ViaLiteHD rack chassis 7HP slot o In a 1U HRK1 rack it fits in slot 3 o In a 3U HRK3 rack it fits in slot 14 DIP switches available for manual alarm screening slots 1 13 and slots 15 16 I2C bus is used at start up to monitor active slots for automatic alarm masking ...

Страница 5: ...of other equipment When fitted in an HRK3 rack chassis it must be fitted in slot 14 this is the only slot to have communication with all other slots ViaLiteHD and ViaLite Classic compatibility The ViaLiteHD summary alarm module will not control or monitor ViaLite Classic equipment Its dry contact relay circuits will be compatible with circuits used on previous ViaLite Classic equipment ...

Страница 6: ...op To install a 7HP Standard module Push the release button of the module handle down and simultaneously pull the top of the handle forwards Align the module upright and perpendicular to the front face of the rack chassis so that the PCB slides into the crow s feet card guides top and bottom Gently push the module down its guide applying pressure via the handle you may also apply pressure between ...

Страница 7: ...ctive The buzzer operates with a nominal frequency of 2 4kHz the tone is modulated 2 2 4 Front panel acknowledge switch The ACKNOWLEDGE switch is housed on the front panel this is used to acknowledge alarms It works in a number of different modes after the alarm is generated depending on the status of the slot module when the acknowledge switch is hit After the ACKNOWLEDGE switch is pressed the su...

Страница 8: ...vailable at the rear of the module The three connections for each relay are NO Normally open COM Common NC Normally closed Connections from Relay 1 are also connected in parallel to the rack chassis backplane The rear panel provides interconnections for two dry contact relays The many be accessed via a six way screwless connector it is suitable for use with 14 22 AWG wire J2 Name ALARM OFF ALARM O...

Страница 9: ...rack Name 3U rack OFF NO Position 1 Unused SET OFF Slot 6 Slot 6 alarms masked Normal operation Position 2 Unused SET OFF Slot 7 Slot 7 alarms masked Normal operation Position 3 Unused SET OFF Slot 8 Slot 8 alarms masked Normal operation Position 4 Unused SET OFF Slot 9 Slot 9 alarms masked Normal operation Position 5 Unused SET OFF Slot 10 Slot 10 alarms masked Normal operation Position 6 Unused ...

Страница 10: ...s to be active The module can provide a maximum load of 12 watts load this load can be switched in 3 watt steps Load 0 3 6 9 12 watts switched Control via switch selection using four DIP switches see section 2 4 Setting 3U rack only 1 or 2 modules fitted all four switches ON 3U rack only 3 or 4 modules fitted three switches ON 3U rack only 5 or 6 modules fitted two switches ON 3U rack only 7 or 8 ...

Страница 11: ...anual alarm masking 2 Set all other DIP switches of SW2 and SW3 to OFF Unpopulated slots will not respond to the I2C pole therefore these will all be masked When in automatic mode manual alarm masking DIP switches SW2 positions 1 8 SW3 positions 2 8 are ignored Setting the load DIP switches Detail of the DIP switch positions are given in section 2 4 2 If you wish to activate any of the resistive l...

Страница 12: ...m tip to push the catch of the 6 way relay connector Wire cutters and stripper to prepare wires for insertion into the 6 way relay connector Suitable stranded 14 22 AWG wire to interface to the 6 way relay connector Full set up details are given in section 3 Site requirements The site will require the following services to make full use of the ViaLiteHD equipment Power source of rack chassis 19 en...

Страница 13: ...PULSE POWER MEASUREMENT LTD 13 5 Mechanical Dimensions Weight 260g Typical 131mm 36mm 204mm ...

Страница 14: ...PULSE POWER MEASUREMENT LTD 14 6 Part Numbering For part numbering please refer to the relevant datasheet which can be found on our website or contact us ...

Страница 15: ...tch selection 4 switches 3 watts per switch Electrical load 0 3 6 9 12 watts Alarm monitoring Manual masking DIP switch selection Automatic masking via I2C sensing at start up Alarm sensing via backplane open collector alarm 13 modules plus 2 power supplies Buzzer frequency 2 4kHz Rear relay port Connector type Screw less 6 terminal connector Wire gauge 14 22 AWG 0 33 2 08 mm2 Relay Relay Type For...

Страница 16: ...Buzzer is sounding A connected modules has an ALARM Fix alarming module OR Press the front panel switch to ACKNOWLEDGE the alarm This will mute the buzzer and change status LED to solid RED Status LED is solid RED A connected modules has an ALARM The alarm has already been acknowledged The ViaLiteHD range is precision engineered and calibrated for optimum performance and accuracy before dispatch I...

Страница 17: ... Internet protocol IP3 Third order intercept point kg Kilo gram kHz Kilo hertz LAN Local area network LASER Light amplification by stimulated emission of radiation LC PC Lucent connector physical contact LED Light emitting diode LNA Low noise amplifier LNB Low noise block m Metre mA Milli ampere Max Maximum MHz Mega hertz Min Minimum mm Milli metre mV Milli volt NC Normally closed NF Noise figure ...

Страница 18: ...hall be as stated in document F292 PPM Manufactured Product Warranty which is available at https ppm co uk warranty periods Extended warranty options are available at the time of purchase Prior to returning any goods for warranty or non warranty repairs please contact PPM ViaLite Communications for a returns reference ...

Страница 19: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense PULSE POWER MEASUREMENT LTD 20...

Отзывы: