![Vexar CEF32M Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vexar/cef32m/cef32m_owners-operation-and-installation-manual_1010626019.webp)
www.desatech.com
113470-01D
19
Figure 35 - Replacing Fixtures (Shown without FIrebox for Clarity)
Screws and
Washers
Hanger
Screws
Reflective
Ribbon
Lamp
Fixture
Crimp
Connectors
Screws
Reflective
Ribbon
Cellophane
Tape
Base
Cover
REPLACING LAMP FIxTURES
Lamp fixtures may be replaced as follows:
1. Turn off all power to fireplace at circuit
breaker or fuse.
2. Locate any of 3 defective lamp fixtures
and trace wiring to crimp connectors in
harness and disconnect.
3. Remove crimp connectors in harness
and disconnect white and black wires on
defective fixture. See
Wiring Diagram
, Fig-
ure 18 on page 11, for proper locations.
4. Remove Phillips screws at base of
defective fixture (see Figure 35).
5. Remove old fixture and mount new fixture
with Phillips screws removed prior.
6. Twist bare ends of white and black wires
to corresponding wires in main harness
and secure them with crimp connectors
provided.
MAINTENANCE
Continued
Note:
There should be no exposed bare
wire at any connection. Wiring should be
secured with wire ties, as short as possible,
and kept away from fan blades. If additional
parts are required, see
Replacement Parts
,
on page 1.
7. Replace each light bulb with proper color,
(see
Replacing Light Bulbs
, page 14).
8. Restore power and check lamp circuit
operation before reassembling imaging
unit.
9. Reassemble imager. See
Accessing
Imaging Unit,
page 15.
Make sure power is turned off
at supply prior to disassembling
this unit.
IMPORTANT:
Be sure to inspect components
and wiring for damage before connecting
power to unit. If any components are found
damaged, contact an authorized dealer for
original DESA replacement part(s) or call
DESA at 1-866-87-6040 for referral.
Upper Hanger
Bracket
Bottom Hanger
Bracket
Ribbon Support
Bracket