Vexar CEF32M Скачать руководство пользователя страница 16

www.desatech.com

113470-01D

16

4.  Lift rear ends of hearth pan up until front 

edge clears lower frame rail then slide 
up  on  end  and  angle  out  of  fireplace 
opening.

5.  Remove  4  Phillips  screws  holding  face 

extensions  at  top  refractory  clips  (see 
Figure 30).

6.  Remove  viewing  screen  from  cabinet 

face. Viewing screen is attached by mag-
nets (see Figure 31).

Note:

 Do not scratch viewing screen. Place 

on  a  nonabrasive  surface  away  from  work 
area. When replacing viewing screen painted 
side must face inside of cabinet with pattern 
facing up.
7.  Remove 4 Phillips screws on base cover 

and lift cover off cabinet base. See Figure 
3, page 17.

Note:

 Only CE3M series models have Face 

Extensions  that  require  removal  to  access 
Imaging  Unit.  Model  CE36M  series  has  in-
ner Face Panels that also require removal to 
access Imaging Unit.

MAINTENANCE

Continued

Figure 29 - Accessing Imaging Unit

Refractory 
Brackets

Grate

Hearth Pan 
Bracket

Hearth Pan 
Bracket

Brick Liner

Brick 
Liner

Figure 30 - Removing Hearth Pan and 

Face Extensions (Extensions for E32 

Series Only)

Hearth Pan

Face Extensions

Refractory Clip

Viewing Screen

Figure 31 - Removing Viewing Screen

Содержание CEF32M

Страница 1: ...d service must be performed by a quali fied service agency ThisproductiscertifiedtoUL2021forindoorinstallationin accordance to national or local building codes In addition thisapplianceisalsoapprovedf...

Страница 2: ...tended 4 Always place main power switch in the off position when not in use 5 Do not operate fireplace if any part has been damaged or is malfunctioning 6 Any repairs to this fireplace should be done...

Страница 3: ...learances see Installation Clear ances page 4 2 Fireplace screen should not be exposed to direct sunlight from windows or doors 3 A 15 amp 120 Volt 60 Hz circuit with proper ground must be available A...

Страница 4: ...allows unit to slide into opening and be nailed to stud at sides and top nailing flanges These flanges accept 5 8 drywall or plywood board to finish unit flush to face Optional trim ac cessories are...

Страница 5: ...th harness to left side while pulling sufficient length of har ness out through control panel cover to reach mounting location on left side 7 Reinsert retaining flange through slot and swing screw mou...

Страница 6: ...with 1 4 of lava rock provided if desired Features and Operation This electronic fireplace series features a random flame effect and a realistic log bed with glistening embers that can be adjusted for...

Страница 7: ...into closed position 6 Repeat steps 1 through 5 for opposite door assembly 7 To adjust doors slide partially open Using a Phillips screwdriver loosen hold down screws on spring clips see Figure 13 8 C...

Страница 8: ...einsert panel Accessory Installation Continued Figure 14 Installing Fixed Glass Doors Spring Clip Locating Hole OPTIONAL BRICK LINERS Installing or Removing Brick Liner Kits These models come standard...

Страница 9: ...g screen rod into locating holes under top edge of firebox and securing with 2 Phillips screws removed in step 2 page 8 Note Rods may have to be angled into locating holes at the top of each screen po...

Страница 10: ...or replace if neces sary See Servicing Flame Pennants page 17 2 Check fan blower for de bris Vacuum areas around blower wheel and remove any obstructions See Main taining Motors page 14 3 Remove and...

Страница 11: ...24 WHT BLK GRN GRN WHT FLAME CONTROL TERMINAL C D A B BLK 5 L 4 LN 1 BLK GRN BLK FAN CONTROL C D B TERMINAL HARNESS 4 BLK REAR HARNESS TO MOTOR CIRCUIT BLK BLK BLK A WHT 5 L BLACK BLK 4 LN 1 MAIN HEA...

Страница 12: ...ount Control Panel Control Cover Blower Mount Control Cover Screws Hex Screws Notches for Control Cover Blower Mount Notch 1 of 4 Screws Figure 20 Mounting Heater Blower Figure 21 Mounting Alternate H...

Страница 13: ...lower mount to holes in control panels and replace the 2 black pan head screws 18 Raise control cover up and position 2 locking tabs through notched openings in firebox top then slide to left until lo...

Страница 14: ...ed over the center opening in between rear screen and front grate CAUTION Make sure power is turned off at supply prior to disassembling this unit Maintaining Motors Motors used on fan and heater asse...

Страница 15: ...slide assembly down through space be tween the front face and firebox mount see detail Figure 28 9 Angle control panel out through opening see Figure 28 10 Follow these instructions in reverse order...

Страница 16: ...painted side must face inside of cabinet with pattern facing up 7 Remove 4 Phillips screws on base cover and lift cover off cabinet base See Figure 32 page 17 Note Only CE32M series models have Face...

Страница 17: ...ug Do not over tighten 9 Attach blade connectors to posts on motor mount Note Wire connectors for fan motor are non polarized and may be connected to either terminal for proper operation Servicing Fla...

Страница 18: ...pennant should not be twisted or tangled and should hang slightly loose to allow free movement If cord is too short or pennant is torn you must obtain a replacement flame assembly see Replacement Part...

Страница 19: ...prior 6 Twist bare ends of white and black wires to corresponding wires in main harness and secure them with 2 crimp connectors provided MAINTENANCE Continued Note There should be no exposed bare wire...

Страница 20: ...ng remove 4 Phillips screws holding corresponding bottom and top hanger brackets see Figure 35 page 19 4 Remove any loose or damaged ribbon material 5 Cut an 18 strip of reflective ribbon and position...

Страница 21: ...his will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA s T...

Страница 22: ...om 113470 01D 22 Illustrated Parts Breakdown Models CEF32M and CEF36M 1 2 3 3 4 5 6 7 8 8 9 10 10 12 12 13 14 14 15 15 16 17 17 17 18 19 20 20 21 22 23 24 25 26 27 27 28 28 29 31 30 30 32 32 33 34 34...

Страница 23: ...ner Bracket 2 18 119089 01 Panel Valance 1 19 110974 01 Junction Box 1 20 M11143 01 Strain Relief Bushing 1 21 Firebox Outer Wrap 1 22 111064 01 Heater Standoff Bracket 1 23 110439 01 Heater Mount 1 1...

Страница 24: ...Parts Breakdown Imaging Unit and Control Panel for Models CEF32M and CEF36M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 19 19 20 21 21 22 23 23 24 25 27 28 30 31 29 26 16 16 16 23 24 25 32 32 36 34...

Страница 25: ...4 114269 01 M4 7 6mm Spring Washer 4 25 114270 01 M5 10mm Flat Washer 4 26 114271 01 M6 10mm Hex Nut 4 27 114272 01 M6 18mm Large Flat Washer 4 28 114273 01 12mm x 15mm Grommet SBR 4 29 114274 01 M6 1...

Страница 26: ...32 Polished Brass PT32P 32 Platinum PT36 36 Black PT36B 36 Brushed Brass PT36PB 36 Polished Brass PT36P 36 Platinum BIFOLD GLASS DOOR KITS BD32B 32 Brushed Brass BD32PB 32 Polished Brass BD32P 32 Pla...

Страница 27: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 28: ...product MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition...

Отзывы: