Type
GHS4SI
GHS6.5SI
GHS8SI
GLS6.5SI GLS14SI
(BWG430) (BWG830) (BWG830) (BWG615E) (BCI184E)
Winding Resistances
Rotor
1,8 Ω
11,9 Ω
11,9 Ω
1,15 Ω
0,64 Ω
Stator, Main Winding per section
0,6 Ω
0,28 Ω
0,28 Ω
0,45 Ω
0,20 Ω
Stator, Auxiliary Winding
2,8 Ω
1,77 Ω
1,77 Ω
20 Ω
20 Ω
Rotor, Auxiliary Winding
0,21 Ω
0,21 Ω
Generator Protection
Main circuit
Automatic fuse (Circuit Breaker)
6 A
20 A
25 A
20 A
50 A
Type
GHS14SI GHS14TI GHS24SI GHS24TI
GLS14TI GLS25TI
(BCI162G) (BCI162E) (BCI182K) (BCI162G) (BCI164D) (BCI184F)
Winding Resistances
Rotor
1,09 Ω
0,89 Ω
1,4 Ω
1,09 Ω
0,56 Ω
0,74 Ω
Main (stator) winding per section
0,10 Ω
0,42 Ω
0,095 Ω
0,21 Ω
0,3 Ω
0,13 Ω
Auxiliary Winding, stator
19 Ω
18 Ω
20 Ω
19 Ω
19 Ω
22 Ω
Auxiliary Winding, rotor
0,27 Ω
0,26 Ω
0,21 Ω
0,27 Ω
0,26 Ω
0,23 Ω
Generator Protection
Main circuit
Automatic fuse (Circuit Breaker)
50 A
3 x 6 A
80 A
3 x 32 A
3 x 6 A
3 x 36 A
N.B.:
All the above information is based on generator sets with a frequency of 50 Hz.
62
Technical Data
8
Содержание GHS14
Страница 307: ...305 10 Hovedm l Huvuddimensioner Viktigste m l P mitoitukset...
Страница 310: ...308 10...
Страница 311: ...309...