090433.01
19
Battery Monitor
ENGLISH
Problem
Possible cause
Solution
An alarm for a too high
voltage.
Voltage is too high.
Check the alternator volt-
age regulator and/or the
battery charger.
The value entered for the
alarm is too low.
Enter a higher value, see
3.6.
6 Technical data
Power supply
: 12 .. 24 V direct current
Power consumption
,
without dial illumination
: 45 mA at 12 V, 30 mA at 24 V
dial illumination
: 55 mA at 12 V, 35 mA at 24 V
Shunt supplied
: 200 A / 100 mV
Protection
: IP66 (only the front of the instrument, after instal-
lation)
Ambient temperature
: 0 .. 50°C
Display
Range
Resolution
Voltage
:
9 .. 32.6 V
0.1 V
Current
:
-200 .. +200 A
0.5 A,
for a 200 A / 100 V shunt
Battery capacity
:
0 .. 100%
0.1% (digital)
Discharge time
:
0 .. 999 hour
0.1 hour
Содержание BATMONB