18
090433.01
Battery Monitor
5 Trouble shooting
Problem
Possible cause
Solution
The minus sign is dis-
played together with the
charging current instead
of the discharge current
Shunt and converter are
incorrect connected.
Reverse the connections
from the shunt to the con-
verter (3 and 4), see 3.1.
Current value is incorrectly
displayed.
Calibration of the instru-
ment is required.
Calibrate the instrument,
see 3.4.
The value entered for the
shunt is incorrect.
Enter the correct value, see
3.3.
Charge condition is incor-
rectly displayed.
The battery capacity en-
tered is incorrect
Enter the correct value, see
3.2.
The 100 % charge condi-
tion has not been entered
with a fully charged bat-
tery.
Enter the 100 % charge
condition correctly, see 3.5
An alarm for a too low
charge condition.
The charge condition is
too low.
Charge the battery.
The value entered for the
alarm is too high.
Enter a lower value, see
3.6.
An alarm for a too low volt-
age.
Voltage is too low.
Charge the battery.
The value entered for the
alarm is too high.
Enter a lower value, see
3.6.