11-9.Control panel buttons not working
Condition:
a). Power supply SP1 is normal (DC5V and DC12V).
b). Emergency Stop is normal and does not be activated.
c). Fuse F3 and F4 are normal.
Replace connection cord CN2 26P
and
CN4 50P on PC board KS-050202-KEY and
then check if normal operation resumes.
NO
Replace PC board KS-050202-KEY and
then check if normal operation resumes.
NO
Replace PC board KS-050202-KEY and
then check if normal operation resumes.
NO
Contact manufacturer.