background image

REV I | 8/6/19

6

If any safety decal is damaged or not readable, shut down the equipment and do not resume operation 

until the decal is replaced. For current pricing and delivery, contact the manufacturer to reorder safety 

decals. 

3.3 

Material Safety

DANGER

:  Do not process flammable, explosive, toxic, or otherwise hazardous materials without first 

performing an appropriate Process Hazard Analysis (PHA).

The  manufacturer  cannot  be  an  expert  in  the  chemical  and  biological  properties  of  the  infinite  number 

of materials that could be handled by this equipment. This equipment is not designed to safely process 

hazardous materials unless additional precautions are taken.

Before processing any materials that are or can react to become flammable, explosive, toxic, or otherwise 

hazardous, the user/owner must perform a thorough risk assessment and Process Hazard Analysis of the 

entire process, including contingency plans for dealing with processing errors and upset conditions.

3.4 

Energy Isolation

DANGER:

 Electrical enclosures contain hazardous voltage that will result in electrical shock or burn. Turn 

off and lock out equipment before servicing.

DANGER:

 Equipment within the electrical enclosure poses a shock and arc flash hazard that may cause 

severe injury or death. Wear proper protective equipment before opening or performing diagnostic 

measurements or testing while energized. Only qualified persons should open or work within the electrical 

enclosure. 
This equipment must have a lockable isolation/relief device for each energy source. If these device(s) 

are not purchased with the equipment, the customer must provide and install a lockable isolation/relief 

device for each energy source (in accordance with federal, state, and local codes/standards).

3.4.1 

Energy Sources

This equipment incorporates separate energy sources. Proper shutdown and lockout/tag-out 

must  only  be  performed  by  qualified  personnel,  and  must  include  disabling  of  all  energy 

sources including but not limited to the following:
NOTE:  Your system may not use all energy sources listed below.

•  Electrical:  Shut off and lock out all electrical disconnects. Verify electrical power is in 

the 

off 

state.

•  Pneumatic:  Disconnect/shut off air supply, bleed air from the equipment, and lock out. 

Verify that energy is relieved/restrained appropriately. 

3.4.2 

Energy Isolation Method

Before adjusting, servicing, repairing, maintaining, or clearing blockages from this equipment, 

complete the procedure below. 
1.  Review and become familiar with all documentation and schematics. Identify energy 

sources and stored energy.

2.  Wear appropriate PPE. 
3.  Fully lower the FLT bucket. 
4. 

Shut off/disconnect the main air supply. Allow air to fully bleed from equipment.

5.  Identify and release stored energy as necessary. 

Содержание AIR-THL

Страница 1: ...he right to make changes to the models from time to time No claims may be made based on the information and illustrations contained in this manual 2 The end user is solely responsible for confirming t...

Страница 2: ...ipment Planning 8 4 2 Inspection of Shipment 8 4 3 Installation Guidelines 8 4 4 Retrofit Packages 9 5 Sequence of Operation 10 5 1 Operating Sequence 10 5 2 Foot Pedal Operation 10 5 3 Hand Valve Ope...

Страница 3: ...identify information on hazards and prevention as well as protection of the equipment DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indica...

Страница 4: ...with Larger Bucket Additional Options 29 186 Caster Retrofit 29 300 Safety Ratchet Retrofit 29 188 Electric Vibrator 29 189 Pneumatic Vibrator Specifications Dimensions 52 x 70 5 x 36 high 132 1 x 17...

Страница 5: ...have been fully trained DO NOT wear any items that could get caught in the moving parts of this equipment Never place any part of your body under or near rotating members or moving parts of machinery...

Страница 6: ...protective equipment before opening or performing diagnostic measurements or testing while energized Only qualified persons should open or work within the electrical enclosure This equipment must hav...

Страница 7: ...REV I 8 6 19 7 6 If applicable Shut off disconnect the main electrical power source 7 Perform your in house lockout tag out procedure 8 Verify that all energy sources are in the off neutral state...

Страница 8: ...if present 4 3 Installation Guidelines NOTICE The customer is responsible for evaluation and guarding of any open sides of the equipment NOTICE All plumbing and wiring must meet or exceed all federal...

Страница 9: ...V I 8 6 19 9 4 4 Retrofit Packages For information on installation and setup of Caster Retrofit 29 186 and Safety Ratchet Retrofit 29 300 packages refer to corresponding Retrofit section of this manua...

Страница 10: ...B into hole on FLT frame and tighten screw at base 4 Insert vacuum wand into wand holder B and into full Gaylord 5 Place pedal hand valve in the inflate position as described below As weight in Gaylo...

Страница 11: ...ce on this equipment ensure that all energy sources are properly isolated as described in the Safety Energy Isolation section 6 2 Maintenance Schedule Periodically grease pivot pin through grease fitt...

Страница 12: ...E by removing nuts G from airbag bolts 6 Disconnect air hose K from airbag 7 Move bucket assembly A slightly forward from frame E to provide space for airbag removal 8 Unbolt and remove airbag H from...

Страница 13: ...assembly under lip of left hand side of frame and move it forward until caster assembly stops Drill holes and mount left caster assembly c Facing rear outside of the frame with caster retracted place...

Страница 14: ...installed on the FLT the FLT unit should be lowered to the floor casters raised before operation CAUTION Casters are only for use in moving FLT when bucket is EMPTY CAUTION Test caster system before...

Страница 15: ...r corner of the bucket I as shown in Figure 5 b Trace the 8 holes on the ratchet bracket M onto the bucket I c Center punch holes traced in previous step d With 21 64 drill bit drill clearance holes i...

Страница 16: ...rame Pivot Tubes 2 C Ball Valve Regulator D Frame E Airbag Bracket F Airbag Pivot Pin G Airbag H Safety Chain I Bucket J Bucket Pivot Tube K Bucket Pivot Pin L Bucket Airbag Pivot M Ratchet Bracket N...

Страница 17: ...ort V Hand Valve 8 1 3 Air Connection Food Pedal 29 900 Connect air to the ratchet as follows 1 Connect the end of the hose segment to the air inlet on the ratchet cylinder 2 Run air hose under bucket...

Страница 18: ...et operation The pawl should move as closely along the ratchet gear as possible without touching the ratchet gear 4 With the ratchet gear positioned as close as possible to the pawl without touching i...

Страница 19: ...Seller reserves the right to satisfy all of its warranty obligations by reimbursing Buyer for all amounts Buyer has paid to Seller for such product upon which Buyer shall immediately return the produ...

Отзывы: